Honeywell Solenoid valve VR425VA5042-0000

SKU VR425VA5042-0000 Brand Honeywell

Photos

Key specifications

Connection threadRp 1
Supply voltage230 V
Inlet and outlet diameter25 mm
Nominal diameter (DN)25 mm
Solenoid configurationsingle solenoid
Coil voltage typeAC/DC
Safety featurerapid closure when power removed
all specifications (7) ↓
984.86 EUR
895.33EUR
in stock · 2

incl. 21% VAT · 739.94 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

This solenoid valve is a single-solenoid model with a 25 mm nominal diameter and an Rp 1 connection thread. It operates on a 230 V AC/DC coil and has a 25 mm inlet/outlet diameter. Designed for the VR425 series, it admits or interrupts gas flow to a burner. When power is removed, the valve closes rapidly to stop gas flow, providing a safety function.

Further details

Applicationgas supply control, gas boilers, burners, heat engineering installations
Burner control activationReceives open signal from burner control after gas pressure switch confirmation
Coil replaceabilityreplaceable without removing valve from line
Coil replaceabilityCoil is often replaceable without removing valve from line
Robust designRobust construction with resistance to temperature and operational loads

Choosing and fitting

Valves of this type are selected primarily by connection size (DN25, equivalent to Rp 1) and by coil voltage, which may be 230 V or 24 V AC/DC depending on the burner control design. The VR425 series includes single-solenoid variants, as well as double-solenoid, slow-opening, servo-regulated, or multiblock versions with integrated filter and regulator. When installing a replacement, match the valve body orientation and flow direction to the original, and check whether the coil can be reused or must be ordered separately; coils are often replaceable without removing the valve from the line.

Signs of failure

Common failure modes include coil burnout from prolonged overvoltage, seat leakage from debris, drifting outlet pressure from a worn servo regulator, and seizure of the solenoid plunger if the gas is contaminated. Such faults can cause the valve to fail to open or close, interrupting or improperly controlling gas flow, which may lead to burner malfunction or safety shutdown.

Fits equipment

Honeywell VR425 series

All specifications

Connection threadRp 1
Supply voltage230 V
Inlet and outlet diameter25 mm
Nominal diameter (DN)25 mm
Solenoid configurationsingle solenoid
Coil voltage typeAC/DC
Safety featurerapid closure when power removed

Part numbers

SKUVR425VA5042-0000
Additional article534.322.344