Brahma Gas solenoid valve 13707512
SKU 13707512
Brand Brahma
Photos
Key specifications
| Nominal diameter (DN) | 15 mm |
|---|---|
| Max. inlet pressure | 950 mbar |
| Connection thread | Rp 1/2" |
| Supply voltage | 230 V |
| Closing time | 1 s |
| Opening time | 1 sec |
| Ingress protection | IP65 |
| Solenoid configuration | V1 and V2 |
| Certification standard | EN 161 |
| Dimensions | 6.5x6.5x9 |
| Directives | 90/396 and 93/68 |
| Flow capacity | 3.9 m³/h |
| Net weight | 0.66 kg |
130.97 EUR
119.06EUR
in stock · 2
incl. 21% VAT · 98.40 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
Brahma Gas solenoid valve 13707512 is a gas valve with a nominal diameter of 15 mm and a connection thread of Rp 1/2". It operates with a supply voltage of 230 V and has a maximum inlet pressure of 950 mbar. The valve has a flow capacity of 3.9 m³/h, a closing time of 1 second, and an opening time of 1 second. It features two solenoid configurations (V1 and V2) and is rated IP65 for ingress protection. The valve weighs 0.66 kg net and has dimensions of 6.5x6.5x9 cm. It is certified to EN 161 and complies with directives 90/396 and 93/68.
Further details
| Flow direction instruction | Install so that the arrow on the valve body coincides with the flow direction. |
|---|---|
| Foreign object prevention | Make sure no foreign objects have entered the valve. |
| Pressure limit instruction | Ensure inlet pressure does not exceed the pressure indicated on the valve. |
| Protective shell | Avoid displacement of the protective shell during installation. |
Choosing and fitting
When selecting a gas solenoid valve of this type, ensure the nominal diameter and connection thread match the existing piping. Verify the supply voltage and maximum inlet pressure are compatible with the system. The valve must be installed with the arrow on the body aligned with the flow direction, and the inlet pressure must not exceed the rated maximum. Use appropriate tools to avoid damaging the protective shell during installation.
Signs of failure
Common failures include the valve failing to open or close, which may result in no gas flow or continuous gas flow. This can be caused by electrical issues, such as incorrect voltage or a faulty solenoid coil, or by mechanical blockage from foreign objects. Check the solenoid connections and ensure the valve is free of debris. If the valve does not respond, verify the control signal and the integrity of the coil.
All specifications
| Nominal diameter (DN) | 15 mm |
|---|---|
| Max. inlet pressure | 950 mbar |
| Connection thread | Rp 1/2" |
| Supply voltage | 230 V |
| Closing time | 1 s |
| Opening time | 1 sec |
| Ingress protection | IP65 |
| Solenoid configuration | V1 and V2 |
| Certification standard | EN 161 |
| Dimensions | 6.5x6.5x9 |
| Directives | 90/396 and 93/68 |
| Flow capacity | 3.9 m³/h |
| Net weight | 0.66 kg |
Part numbers
| SKU | 13707512 |
|---|---|
| Additional article | 246.322.034 |