{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Brahma Gas solenoid valve 13747001

SKU 13747001 Brand Brahma

Photos

Key specifications

Nominal diameter (DN)8 mm
Supply voltage230 V
Closing time1 s
Installation positionvertical and horizontal
Body materialbrass
Power supply typealternating current
Opening typequick opening, silent
Electrical connectionterminal block connection - ip54
Valve classa
Installation standardEN 60335-1
Flow direction markingarrow on the valve body
Protective shellavoid displacement
Hex key requirementuse the appropriate size
Foreign object preventionprevent foreign objects from entering
Normally closednormally closed type
Nozzle diameter8 mm
Applicationdomestic and industrial installations
Current typedirect and alternating current
Directives90/396 and 93/68
Rectifierbuilt-in bridge rectifier circuit
Silent operationsilent
Frequency50–60 Hz
Power consumption20 W
Flow capacity2 m³/h
Net weight0.7 kg
all specifications (25) ↓
122.98 EUR
111.80EUR
in stock · 5

incl. 21% VAT · 92.40 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Brahma Gas solenoid valve 13747001 is a normally closed gas valve with a nominal diameter of 8 mm and a nozzle diameter of 8 mm. It operates on a supply voltage of 230 V AC with a frequency of 50–60 Hz, consuming 20 W. The valve has a flow capacity of 2 m³/h, a closing time of 1 second, and a net weight of 0.7 kg. It features a brass body, quick and silent opening, and is suitable for vertical and horizontal installation. The valve is designed for domestic and industrial applications and complies with directives 90/396 and 93/68.

Further details

Pressure Limit Instructioninlet pressure does not exceed the value set on the valve

Choosing and fitting

Parts of this type are selected by matching the nominal diameter, supply voltage, and flow capacity to the system requirements. Installation must follow standard EN 60335-1, ensuring the arrow on the valve body aligns with the flow direction. The valve can be mounted vertically or horizontally, but avoid displacement of the protective shell and use the appropriate hex key size. Prevent foreign objects from entering the valve during installation.

Signs of failure

Common failure modes for gas solenoid valves include coil burnout, sticking due to debris, or diaphragm damage, leading to the valve failing to open or close properly. Symptoms may include no gas flow, continuous gas flow, or irregular burner operation. Check the electrical connections, coil resistance, and cleanliness of the valve interior.

All specifications

Nominal diameter (DN)8 mm
Supply voltage230 V
Closing time1 s
Installation positionvertical and horizontal
Body materialbrass
Power supply typealternating current
Opening typequick opening, silent
Electrical connectionterminal block connection - ip54
Valve classa
Installation standardEN 60335-1
Flow direction markingarrow on the valve body
Protective shellavoid displacement
Hex key requirementuse the appropriate size
Foreign object preventionprevent foreign objects from entering
Normally closednormally closed type
Nozzle diameter8 mm
Applicationdomestic and industrial installations
Current typedirect and alternating current
Directives90/396 and 93/68
Rectifierbuilt-in bridge rectifier circuit
Silent operationsilent
Frequency50–60 Hz
Power consumption20 W
Flow capacity2 m³/h
Net weight0.7 kg

Part numbers

SKU13747001
Additional article246.322.022