Brahma Gas solenoid valve 13763802
SKU 13763802
Brand Brahma
Photos
Key specifications
| Connection thread | 1/2 |
|---|---|
| Supply voltage | 230 V |
| Closing time | 1 s |
| Opening time | 1 sec |
| Body material | brass |
| Power supply type | alternating current |
| Opening type | quick opening, silent |
| Installation position | vertical and horizontal |
| Certification standard | EN161 |
| Valve class | a |
| Current type | direct and alternating current |
| Nozzle diameter | 8–10 mm |
| Directives | 90/396 and 93/68 |
| Installation standard | EN 60335-1 |
| Flow direction marking | arrow on the valve body |
| Rectifier | built-in bridge rectifier circuit |
| Short name | Brahma 13763802 E6G*SRP10*1/2*GFD5 gas valve |
| SKU (English) | 13763802, 246.322.054 |
| Normally closed | yes |
| Application | domestic and industrial installations |
| Silent operation | yes |
| Flow adjustment | clockwise reduce, counterclockwise increase |
| Electrical safety | EN 60335-1 |
| Protective shell | avoid displacement |
| Frequency | 50–60 Hz |
137.36 EUR
124.87EUR
in stock · 2
incl. 21% VAT · 103.20 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma 13763802 E6G*SRP10*1/2*GFD5 is a normally closed gas solenoid valve with a 1/2-inch connection thread. It operates on 230 V AC at 50–60 Hz, with a built-in bridge rectifier circuit allowing control via DC signal. The valve features quick, silent opening and closing times of 1 second each, and is made of brass. It is certified to EN161 and complies with directives 90/396 and 93/68, suitable for domestic and industrial installations. The valve can be installed vertically or horizontally and includes a flow adjustment mechanism.
Further details
| Connection Type | quick-release connection for din43650 - ip65 (gfd ip40) |
|---|---|
| Flow Settings | the valve has the ability to adjust the flow rate |
| Foreign Object Prevention | make sure that no foreign objects have entered the valve |
| Hex Key Requirement | use a hex key of the appropriate size |
| Inlet pressure limit | do not exceed pressure indicated on valve |
| Pressure Limit Instruction | inlet pressure does not exceed the pressure indicated on the valve |
Choosing and fitting
When selecting a gas solenoid valve of this type, ensure the connection thread size, supply voltage, and frequency match the system requirements. The valve body material and certification standard (e.g., EN161) must be compatible with the application. Installation should follow the arrow on the body for correct flow direction, and the valve must be mounted without displacing the protective shell, using a proper hex key. The inlet pressure must not exceed the rated pressure indicated on the valve.
Signs of failure
Common failure modes for gas solenoid valves include coil burnout, sticking due to debris, or diaphragm damage, leading to failure to open or close properly. Symptoms may include no gas flow when the valve should be open, or gas flow when it should be closed, causing burner ignition issues or unsafe operation. Check for continuity in the coil, ensure the valve is clean, and verify that the inlet pressure is within specifications.
All specifications
| Connection thread | 1/2 |
|---|---|
| Supply voltage | 230 V |
| Closing time | 1 s |
| Opening time | 1 sec |
| Body material | brass |
| Power supply type | alternating current |
| Opening type | quick opening, silent |
| Installation position | vertical and horizontal |
| Certification standard | EN161 |
| Valve class | a |
| Current type | direct and alternating current |
| Nozzle diameter | 8–10 mm |
| Directives | 90/396 and 93/68 |
| Installation standard | EN 60335-1 |
| Flow direction marking | arrow on the valve body |
| Rectifier | built-in bridge rectifier circuit |
| Short name | Brahma 13763802 E6G*SRP10*1/2*GFD5 gas valve |
| SKU (English) | 13763802, 246.322.054 |
| Normally closed | yes |
| Application | domestic and industrial installations |
| Silent operation | yes |
| Flow adjustment | clockwise reduce, counterclockwise increase |
| Electrical safety | EN 60335-1 |
| Protective shell | avoid displacement |
| Frequency | 50–60 Hz |
Part numbers
| SKU | 13763802 |
|---|---|
| Additional article | 246.322.054 |