Brahma Gas valve 13992323
SKU 13992323
Brand Brahma
Photos
Key specifications
| Nominal diameter (DN) | 25 mm |
|---|---|
| Max. inlet pressure | 350 mbar |
| Connection thread | Rp 3/4" |
| Supply voltage | 230 V |
| Closing time | 1 s |
| Ingress protection | IP40 |
| Dimensions | 18.3x21.8x19 cm |
| Electrical connection | DIN plug |
| Valve classification | class A |
| Purpose | gas burners |
| Bypass valve | can be equipped |
| Gas pressure sensor | fixed or adjustable set value |
| Inlet pressure regulator | present |
| Printed circuit board | in plastic housing |
| Signal LED | present |
| Flow direction marking | arrow on valve body |
| Hex key requirement | use hexagonal key |
| Foreign object prevention | ensure no foreign objects |
| Pressure limit instruction | do not exceed label value |
| Power consumption | 83 W |
881.65 EUR
801.50EUR
in stock · 1
incl. 21% VAT · 662.40 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma Gas valve 13992323 is a gas valve designed for gas burners. It has a nominal diameter of 25 mm and a connection thread of Rp 3/4". The maximum inlet pressure is 350 mbar, and it operates on a supply voltage of 230 V with a power consumption of 83 W. The valve has a closing time of 1 second and an ingress protection rating of IP40. It features a DIN plug for electrical connection, a signal LED, and a printed circuit board in a plastic housing. The valve is classified as class A and can be equipped with a bypass valve and a gas pressure sensor with fixed or adjustable set value. It also includes an inlet pressure regulator. The flow direction is marked by an arrow on the valve body. Installation requires using a hexagonal key and ensuring no foreign objects enter the housing. The maximum fuel input pressure must not exceed the value indicated on the product label. The valve complies with relevant standards such as EN60335-1 regarding electrical safety.
Choosing and fitting
Parts of this type are selected by matching the nominal diameter, connection thread, supply voltage, and maximum inlet pressure to the existing system. The valve must be installed so that the arrow on the body aligns with the fuel flow direction. Use a hexagonal key on the valve body to avoid twisting the sheath. Ensure no foreign objects enter the housing and that the maximum fuel input pressure does not exceed the label value.
Fits equipment
EN60335-1) regarding electrical safety.
All specifications
| Nominal diameter (DN) | 25 mm |
|---|---|
| Max. inlet pressure | 350 mbar |
| Connection thread | Rp 3/4" |
| Supply voltage | 230 V |
| Closing time | 1 s |
| Ingress protection | IP40 |
| Dimensions | 18.3x21.8x19 cm |
| Electrical connection | DIN plug |
| Valve classification | class A |
| Purpose | gas burners |
| Bypass valve | can be equipped |
| Gas pressure sensor | fixed or adjustable set value |
| Inlet pressure regulator | present |
| Printed circuit board | in plastic housing |
| Signal LED | present |
| Flow direction marking | arrow on valve body |
| Hex key requirement | use hexagonal key |
| Foreign object prevention | ensure no foreign objects |
| Pressure limit instruction | do not exceed label value |
| Power consumption | 83 W |
Part numbers
| SKU | 13992323 |
|---|---|
| Additional article | 246.322.046 |