Brahma Gas solenoid valve GVC 40*S*L 13992908
SKU 13992908
Model GVC 40*S*L
Brand Brahma
Photos
Key specifications
| Max. inlet pressure | 200 mbar |
|---|---|
| Connection thread | Rp 1 1/2" |
| Supply voltage | 230 V |
| Closing time | 1 s |
| Ambient temperature | -10–60 °C |
| Ingress protection | IP 40 |
| Electrical connection | four-pin MPM connector |
| Valve classification | class a |
| Bypass valve | yes |
| Gas pressure sensor | fixed or adjustable |
| Inlet pressure regulator | yes |
| Printed circuit board | in plastic case |
| Signal LED | yes |
| connection_type | DIN plug |
| Power consumption | 97 W |
975.89 EUR
887.17EUR
in stock · 1
incl. 21% VAT · 733.20 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
Brahma GVC 40*S*L gas solenoid valve, SKU 13992908, is a Class A gas valve with a bypass valve, gas pressure sensor (fixed or adjustable), and inlet pressure regulator. It operates with a supply voltage of 230 V, consumes 97 W, and has a closing time of 1 second. The valve features a four-pin MPM connector, a printed circuit board in a plastic case, and a signal LED. It is rated for a maximum inlet pressure of 200 mbar, has an Rp 1 1/2" connection thread, and is protected to IP 40.
Choosing and fitting
When selecting a replacement gas solenoid valve of this type, ensure the connection thread size matches the existing piping (e.g., Rp 1 1/2"). Verify the supply voltage (e.g., 230 V) and power consumption are compatible with the control system. Check the inlet pressure rating (e.g., 200 mbar) and ambient temperature range (e.g., -10 to 60 °C) to suit the installation environment. Confirm the electrical connection type (e.g., four-pin MPM connector) and whether the valve includes features like a bypass or pressure regulator as required.
Signs of failure
Common failures in gas solenoid valves of this kind include coil burnout, leading to the valve not opening or closing properly, which may cause burner ignition failure or gas flow interruption. A faulty pressure sensor or regulator can result in unstable gas pressure, causing flame fluctuations or burner lockout. Electrical connection issues, such as loose or corroded pins, may trigger intermittent operation or no response. Check the signal LED for error indications and verify the valve's closing time and power consumption to diagnose electrical faults.
All specifications
| Max. inlet pressure | 200 mbar |
|---|---|
| Connection thread | Rp 1 1/2" |
| Supply voltage | 230 V |
| Closing time | 1 s |
| Ambient temperature | -10–60 °C |
| Ingress protection | IP 40 |
| Electrical connection | four-pin MPM connector |
| Valve classification | class a |
| Bypass valve | yes |
| Gas pressure sensor | fixed or adjustable |
| Inlet pressure regulator | yes |
| Printed circuit board | in plastic case |
| Signal LED | yes |
| connection_type | DIN plug |
| Power consumption | 97 W |
Part numbers
| SKU | 13992908 |
|---|---|
| Additional article | 246.322.087 |
| Model | GVC 40*S*L |