Honeywell Gas solenoid valve VK4115VB2007U

SKU VK4115VB2007U Model VK4115VB2007 Brand Honeywell

Photos

Key specifications

Ambient pressure1013 mbar
Built-in filterfine-mesh filter
connection_typeflanged
Control featureselectric two-level regulator
Control typepressure control by servo drive
Diaphragm diameter2.8 mm
Filter cleaningnot intended for cleaning
Mounting featureholes at the bottom
Normal statenormally closed
Optional output filtercan be added
Design featurespositive feedback system
Electrical connectionconnector or plug-in rectifier unit
Flange collector requiredflanged burner manifold required
Flanged connectionsflanged
Gas typeheating, natural and liquefied
Housing typestandard housing
Inlet and outlet diameter18.6 mm
Nominal inlet gas pressure25 mbar
Operating voltage24 V
Operating positionupright
Output aperture diameter2.8 mm
Output pressure stabilitystable output pressure
Pilot gas connection diameter4 mm
Pressure relief valvepressure relief valve
Pressure sensor pipe diameter0.5 inch
Pressure servo controllerpressure servo controller
Regulation of the mixture of gas and air in a ratio of 11
Smooth regulation with amplificationsmooth regulation with amplification
Softlite technologysmooth ignition using softlite technology
Throttle valve regulationregulation via the throttle valve
Two electrical devicestwo electrical devices
Standard DBI ignition systemsplug-in rectifier unit
Flow indicationcubic meters per hour
all specifications (33) ↓
230.02 EUR
209.11EUR
in stock · 3

incl. 21% VAT · 172.82 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

This normally closed gas solenoid valve is designed for burner control and ignition systems, regulating gas flow to both pilot and main burner for heating, natural, and liquefied gas. It operates on 24 V, with a nominal inlet pressure of 25 mbar and ambient pressure of 1013 mbar. The valve has flanged connections with an inlet/outlet diameter of 18.6 mm, a pilot gas connection of 4 mm, and an output aperture of 2.8 mm. It features pressure control by a servo drive, an electric two-level regulator, throttle valve regulation, smooth ignition via Softlite technology, and 1:1 gas/air ratio regulation. The valve includes two electrical devices, a fine-mesh inlet filter (not intended for cleaning), an optional output filter, and a positive feedback system with pressure servo controller and pressure relief valve for stable output pressure. Gas consumption is indicated in cubic meters per hour, mounting is upright with holes at the bottom, and electrical connection is via connector or plug-in rectifier unit for standard DBI ignition systems.

Further details

Closing Variantsb + j, b + c, b + b
Ignition regulator exceptionexcept regulators of the s4565/s4585 series
Included Componentsvk4115vb 2007 valve and specialized ignition regulator
Operating Principlegas passes through servo controller and opens main valve
Outlet Orientationside outlet for main and pilot burner
Output pressure stabilitystable output pressure, even with changes in the input pressure
Pressure Measuring Fittingssilicone tubes 4 or 6 mm
Pressure Relief Valvepressure servo controller and pressure relief valve
Safety Featuremain valve automatically closes when no power or gas pressure exceeded
Smooth regulation with amplificationsmooth regulation with amplification for various control methods
Two Electrical Devicestwo electrical devices: one for main valve, one for position control

Choosing and fitting

When selecting a replacement gas solenoid valve of this type, ensure the flanged connection matches the existing pipe size (inlet/outlet), and verify the pilot gas connection and pressure sensor pipe diameters. The valve must be installed upright, secured through the mounting holes at the bottom. Electrical connections can be made via connector or plug-in rectifier unit; confirm the required operating voltage (24V optional) and whether an additional output filter is needed. If a side outlet is used, a flanged burner manifold is required.

All specifications

Ambient pressure1013 mbar
Built-in filterfine-mesh filter
connection_typeflanged
Control featureselectric two-level regulator
Control typepressure control by servo drive
Diaphragm diameter2.8 mm
Filter cleaningnot intended for cleaning
Mounting featureholes at the bottom
Normal statenormally closed
Optional output filtercan be added
Design featurespositive feedback system
Electrical connectionconnector or plug-in rectifier unit
Flange collector requiredflanged burner manifold required
Flanged connectionsflanged
Gas typeheating, natural and liquefied
Housing typestandard housing
Inlet and outlet diameter18.6 mm
Nominal inlet gas pressure25 mbar
Operating voltage24 V
Operating positionupright
Output aperture diameter2.8 mm
Output pressure stabilitystable output pressure
Pilot gas connection diameter4 mm
Pressure relief valvepressure relief valve
Pressure sensor pipe diameter0.5 inch
Pressure servo controllerpressure servo controller
Regulation of the mixture of gas and air in a ratio of 11
Smooth regulation with amplificationsmooth regulation with amplification
Softlite technologysmooth ignition using softlite technology
Throttle valve regulationregulation via the throttle valve
Two electrical devicestwo electrical devices
Standard DBI ignition systemsplug-in rectifier unit
Flow indicationcubic meters per hour

Part numbers

SKUVK4115VB2007U
Additional article534.331.921
ModelVK4115VB2007