Key specifications
| Max. inlet pressure | 60 mbar |
|---|---|
| Supply voltage | 220–240 V |
| Output pressure range | 2.5–20 mbar |
| Ambient temperature | 0–70 °C |
| Safety feature | thermoelectric protection |
| Actuator type | Fast opening electromagnet |
| Gas type | natural and liquefied gas |
| Softlite technology | Softlite diaphragm |
| Application | Burner systems |
| Pilot type | standing pilot |
| Coil replaceability | Replaceable separately from valve body |
| Voltage | 230 V |
| Frequency | 50–60 Hz |
282.30 EUR
256.64EUR
in stock · 1
incl. 21% VAT · 212.10 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Honeywell V4600C1086U is a gas valve intended for burner systems. It operates with a supply voltage of 220–240 V at 50–60 Hz. Maximum inlet pressure is 60 mbar, and the outlet pressure can be adjusted from 2.5 to 20 mbar, accommodating natural and liquefied gas. The valve uses a fast-opening electromagnet and incorporates a Softlite diaphragm. Safety is provided by thermoelectric protection with a standing pilot. The coil is replaceable separately from the valve body.
Further details
| Connection Thread | internal thread 1/2" x 1/2" BSP |
|---|---|
| Operating principle | Opens on command from burner control; gas pressure switch confirmation required |
Choosing and fitting
When replacing a valve of this kind, note the connection size and coil voltage of the existing installation to ensure the new part matches. The coil is often replaceable separately from the valve body, allowing it to be swapped independently if needed. Before fitting, verify that the valve's specifications align with the system's requirements.
Signs of failure
Typical failures include coil burnout, a leaking seat, drifting outlet pressure, and a seized servo regulator. Symptoms may involve intermittent operation or the safety system shutting off fuel supply. Check the coil, inspect the seat for leaks, and verify outlet pressure to diagnose the issue.
All specifications
| Max. inlet pressure | 60 mbar |
|---|---|
| Supply voltage | 220–240 V |
| Output pressure range | 2.5–20 mbar |
| Ambient temperature | 0–70 °C |
| Safety feature | thermoelectric protection |
| Actuator type | Fast opening electromagnet |
| Gas type | natural and liquefied gas |
| Softlite technology | Softlite diaphragm |
| Application | Burner systems |
| Pilot type | standing pilot |
| Coil replaceability | Replaceable separately from valve body |
| Voltage | 230 V |
| Frequency | 50–60 Hz |
Part numbers
| SKU | V4600C1086U |
|---|---|
| Additional article | 534.322.011 |
| Model | V4600C1086 |
| Superseded number | V4600 |