Honeywell Gas valve V4600C1193U

SKU V4600C1193U Model V4600C1193 Brand Honeywell

Photos

Key specifications

Supply voltage220–240 V
Maximum inlet pressure60 mbar
Pilot typestanding pilot
Operating temperature0 °C
Protection class (IP)J
Pressure categoryIII
Current consumption0.02 A
Operating principleservo-controlled
Frequency50 Hz
Certificationce-0063ap3090/3
all specifications (10) ↓
297.00 EUR
270.00EUR
in stock · 1

incl. 21% VAT · 223.14 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

This is a servo-controlled combination gas valve for boilers and water heaters. It combines a pilot flame control (pilotstat), a servo actuator valve, and a pressure regulator in one housing. The valve is designed for standing-pilot operation with a Honeywell pilot burner, thermocouple, and thermal relay, and it supplies gas to the main burner only when the pilot flame is present. Technical specifications: maximum inlet pressure 60 mbar (pressure category III); supply voltage 220–240 V, 50 Hz, 0.02 A; operating temperature 0 °C; protection class J; certification CE-0063AP3090/3.

Further details

Applicationdomestic central heating systems, natural draft heating furnaces, hot water boilers, and water heaters
Included componentspilot flame control (pilotstat), servo actuator valve, pressure regulator
Output Pressure Stabilitystabilizes outlet pressure regardless of inlet pressure fluctuations
Safety Featureinstant gas shut-off in case of flame failure or power loss

Choosing and fitting

When selecting a replacement for this type of gas valve, match the brand and series, connection size (typically Rp 1/2" to 2" or flanged), coil voltage (230 V or 24 V AC/DC), and function — single or double solenoid, slow opening, servo-regulated, or multiblock with integral filter and regulator. The coil is often replaceable separately from the valve body, which can simplify servicing if the coil fails. Always verify electrical compatibility and mechanical connections, and confirm that the burner control sequence matches the valve's opening characteristics.

Signs of failure

Typical failures of items of this kind include leaking seat and drifting outlet pressure. A seized servo regulator is also a common failure mode.

All specifications

Supply voltage220–240 V
Maximum inlet pressure60 mbar
Pilot typestanding pilot
Operating temperature0 °C
Protection class (IP)J
Pressure categoryIII
Current consumption0.02 A
Operating principleservo-controlled
Frequency50 Hz
Certificationce-0063ap3090/3

Part numbers

SKUV4600C1193U
Additional article534.322.053