Honeywell Gas valve V4600C1193U
SKU V4600C1193U
Model V4600C1193
Brand Honeywell
Photos
Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Maximum inlet pressure | 60 mbar |
| Pilot type | standing pilot |
| Operating temperature | 0 °C |
| Protection class (IP) | J |
| Pressure category | III |
| Current consumption | 0.02 A |
| Operating principle | servo-controlled |
| Frequency | 50 Hz |
| Certification | ce-0063ap3090/3 |
297.00 EUR
270.00EUR
in stock · 1
incl. 21% VAT · 223.14 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
This is a servo-controlled combination gas valve for boilers and water heaters. It combines a pilot flame control (pilotstat), a servo actuator valve, and a pressure regulator in one housing. The valve is designed for standing-pilot operation with a Honeywell pilot burner, thermocouple, and thermal relay, and it supplies gas to the main burner only when the pilot flame is present. Technical specifications: maximum inlet pressure 60 mbar (pressure category III); supply voltage 220–240 V, 50 Hz, 0.02 A; operating temperature 0 °C; protection class J; certification CE-0063AP3090/3.
Further details
| Application | domestic central heating systems, natural draft heating furnaces, hot water boilers, and water heaters |
|---|---|
| Included components | pilot flame control (pilotstat), servo actuator valve, pressure regulator |
| Output Pressure Stability | stabilizes outlet pressure regardless of inlet pressure fluctuations |
| Safety Feature | instant gas shut-off in case of flame failure or power loss |
Choosing and fitting
When selecting a replacement for this type of gas valve, match the brand and series, connection size (typically Rp 1/2" to 2" or flanged), coil voltage (230 V or 24 V AC/DC), and function — single or double solenoid, slow opening, servo-regulated, or multiblock with integral filter and regulator. The coil is often replaceable separately from the valve body, which can simplify servicing if the coil fails. Always verify electrical compatibility and mechanical connections, and confirm that the burner control sequence matches the valve's opening characteristics.
Signs of failure
Typical failures of items of this kind include leaking seat and drifting outlet pressure. A seized servo regulator is also a common failure mode.
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Maximum inlet pressure | 60 mbar |
| Pilot type | standing pilot |
| Operating temperature | 0 °C |
| Protection class (IP) | J |
| Pressure category | III |
| Current consumption | 0.02 A |
| Operating principle | servo-controlled |
| Frequency | 50 Hz |
| Certification | ce-0063ap3090/3 |
Part numbers
| SKU | V4600C1193U |
|---|---|
| Additional article | 534.322.053 |
| Model | V4600C1193 |