Honeywell Gas valve VK4100A1002U
SKU VK4100A1002U
Brand Honeywell
Photos
Key specifications
| Max. inlet pressure | 60 mbar |
|---|---|
| Connection thread | flanged |
| Regulation of gas and air with a ratio of 1 | 1 |
| Ambient temperature | -15–60 °C |
| Maximum working pressure | 45 bar |
| Outlet Orientation | side |
| Diaphragm diameter | 2.8 mm |
| Pilot gas connection diameter | 4 mm |
| Inlet and outlet diameter | 18.6 mm |
| Back pressure (1st valve) | 50 mbar |
| Nominal inlet gas pressure | 25 mbar |
| Pressure sensor pipe diameter | 0.5 inch |
| Maximum inlet pressure | 60 mbar |
| Maximum operating pressure | 45 mbar |
| Compression fitting | 4 mm |
| Max operating pressure | 45 mbar |
| Ambient pressure | 1013 mbar |
| Output aperture diameter | 2.8 mm |
167.71 EUR
152.46EUR
in stock · 1
incl. 21% VAT · 126.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Honeywell VK4100A1002U is a combined gas valve for burner control and ignition systems, providing safe ignition, flame control, and gas flow regulation for pilot and/or main burners. It features regulation of gas and air with a 1:1 ratio, operates within an ambient temperature range of -15 to 60 °C, and has a maximum working pressure of 45 mbar. The valve has a flanged connection thread, with inlet and outlet diameters of 18.6 mm, and a side outlet orientation. It includes a pilot gas connection diameter of 4 mm, a diaphragm diameter of 2.8 mm, and a pressure sensor pipe diameter of 0.5 inch. Nominal inlet pressure is 25 mbar, with maximum inlet pressure of 60 mbar, and back pressure on the 1st valve is 50 mbar. The compression fitting is 4 mm, and ambient pressure is 1013 mbar.
Further details
| Back pressure | 1st valve: 50 mbar; 2nd valve: 0 mbar |
|---|---|
| Control flow rate | 0.1 mph (min) of air at a pressure drop of 9 mbar |
| Gas connection | Inlet: diameter 18.6 mm Outlet: side outlet diameter 18.6 mm: - |
| Leakage requirements | According to EN126 |
| Performance (by air) | 3.4 miles/3 mbar thermal pressure drop |
| Pressure valve | Top for measuring inlet and outlet pressure |
| Screen | On the input side |
Choosing and fitting
Parts of this type are selected by matching the connection thread and diameters to the existing piping, ensuring the inlet and outlet sizes align with the burner manifold. The valve must be compatible with the gas type and pressure requirements of the system. Installation involves checking the orientation (side outlet) and securing flanged connections. Before ordering, verify the maximum working pressure and inlet pressure ratings against the system's specifications.
Signs of failure
Common failure modes for gas valves of this kind include failure to open or close properly, leading to no gas flow or continuous flow. Symptoms may include burner ignition failure, unstable flame, or inability to modulate gas pressure. Check for electrical continuity, diaphragm integrity, and blockages in the pilot gas connection or pressure sensor lines.
All specifications
| Max. inlet pressure | 60 mbar |
|---|---|
| Connection thread | flanged |
| Regulation of gas and air with a ratio of 1 | 1 |
| Ambient temperature | -15–60 °C |
| Maximum working pressure | 45 bar |
| Outlet Orientation | side |
| Diaphragm diameter | 2.8 mm |
| Pilot gas connection diameter | 4 mm |
| Inlet and outlet diameter | 18.6 mm |
| Back pressure (1st valve) | 50 mbar |
| Nominal inlet gas pressure | 25 mbar |
| Pressure sensor pipe diameter | 0.5 inch |
| Maximum inlet pressure | 60 mbar |
| Maximum operating pressure | 45 mbar |
| Compression fitting | 4 mm |
| Max operating pressure | 45 mbar |
| Ambient pressure | 1013 mbar |
| Output aperture diameter | 2.8 mm |
Part numbers
| SKU | VK4100A1002U |
|---|---|
| Additional article | 534.322.195 |