Honeywell Gas valve VK4100A1002U

SKU VK4100A1002U Brand Honeywell

Photos

Key specifications

Max. inlet pressure60 mbar
Connection threadflanged
Regulation of gas and air with a ratio of 11
Ambient temperature-15–60 °C
Maximum working pressure45 bar
Outlet Orientationside
Diaphragm diameter2.8 mm
Pilot gas connection diameter4 mm
Inlet and outlet diameter18.6 mm
Back pressure (1st valve)50 mbar
Nominal inlet gas pressure25 mbar
Pressure sensor pipe diameter0.5 inch
Maximum inlet pressure60 mbar
Maximum operating pressure45 mbar
Compression fitting4 mm
Max operating pressure45 mbar
Ambient pressure1013 mbar
Output aperture diameter2.8 mm
all specifications (18) ↓
167.71 EUR
152.46EUR
in stock · 1

incl. 21% VAT · 126.00 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Honeywell VK4100A1002U is a combined gas valve for burner control and ignition systems, providing safe ignition, flame control, and gas flow regulation for pilot and/or main burners. It features regulation of gas and air with a 1:1 ratio, operates within an ambient temperature range of -15 to 60 °C, and has a maximum working pressure of 45 mbar. The valve has a flanged connection thread, with inlet and outlet diameters of 18.6 mm, and a side outlet orientation. It includes a pilot gas connection diameter of 4 mm, a diaphragm diameter of 2.8 mm, and a pressure sensor pipe diameter of 0.5 inch. Nominal inlet pressure is 25 mbar, with maximum inlet pressure of 60 mbar, and back pressure on the 1st valve is 50 mbar. The compression fitting is 4 mm, and ambient pressure is 1013 mbar.

Further details

Back pressure1st valve: 50 mbar; 2nd valve: 0 mbar
Control flow rate0.1 mph (min) of air at a pressure drop of 9 mbar
Gas connectionInlet: diameter 18.6 mm Outlet: side outlet diameter 18.6 mm: -
Leakage requirementsAccording to EN126
Performance (by air)3.4 miles/3 mbar thermal pressure drop
Pressure valveTop for measuring inlet and outlet pressure
ScreenOn the input side

Choosing and fitting

Parts of this type are selected by matching the connection thread and diameters to the existing piping, ensuring the inlet and outlet sizes align with the burner manifold. The valve must be compatible with the gas type and pressure requirements of the system. Installation involves checking the orientation (side outlet) and securing flanged connections. Before ordering, verify the maximum working pressure and inlet pressure ratings against the system's specifications.

Signs of failure

Common failure modes for gas valves of this kind include failure to open or close properly, leading to no gas flow or continuous flow. Symptoms may include burner ignition failure, unstable flame, or inability to modulate gas pressure. Check for electrical continuity, diaphragm integrity, and blockages in the pilot gas connection or pressure sensor lines.

All specifications

Max. inlet pressure60 mbar
Connection threadflanged
Regulation of gas and air with a ratio of 11
Ambient temperature-15–60 °C
Maximum working pressure45 bar
Outlet Orientationside
Diaphragm diameter2.8 mm
Pilot gas connection diameter4 mm
Inlet and outlet diameter18.6 mm
Back pressure (1st valve)50 mbar
Nominal inlet gas pressure25 mbar
Pressure sensor pipe diameter0.5 inch
Maximum inlet pressure60 mbar
Maximum operating pressure45 mbar
Compression fitting4 mm
Max operating pressure45 mbar
Ambient pressure1013 mbar
Output aperture diameter2.8 mm

Part numbers

SKUVK4100A1002U
Additional article534.322.195