Honeywell Gas valve VK4100Q2003B

SKU VK4100Q2003B Model VK4100Q2003 Brand Honeywell

Photos

Key specifications

Max. inlet pressure60 mbar
Connection threadflanged
Regulation of the gas and air mixture in an ideal 11 ratio
Compression fitting4 mm
Ambient temperature-15–60 °C
Maximum inlet pressure60 mbar
Maximum operating pressure30 mbar
Inlet and outlet diameter18.6 mm
Back pressure (1st valve)50 mbar
Leakage requirementsen126
Ambient pressure1013 mbar
Input screenon the input side
Two electrical devicestwo electronic devices
Pressure drop3 mbar
Softlite time1.5 sec.
Ignition regulator exceptions4565/s4585 series
Pilot flowpresent
Flow capacity3.4 m³/h
all specifications (18) ↓
160.49 EUR
145.90EUR
in stock · 13

incl. 21% VAT · 120.58 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Honeywell VK4100Q2003B is a gas valve designed for burner control and ignition systems, regulating gas flow for both pilot and main burner. It features a 1:1 gas-air ratio regulation, a compression fitting of 4 mm, and operates within an ambient temperature range of -15 to 60 °C. The valve has a maximum inlet pressure of 60 mbar and a maximum operating pressure of 30 mbar, with a flow capacity of 3.4 m³/h at a pressure drop of 3 mbar. It includes two electronic devices for valve control and position monitoring, and supports flanged connections with an inlet/outlet diameter of 18.6 mm. The valve has a back pressure of 50 mbar on the first valve, meets leakage standard EN126, and includes a pilot flow feature.

Further details

Back pressure1st valve: 50 mbar; 2nd valve: 0 mbar
Capacity (by air)3.4 m3/h with a pressure drop of 3 mbar
Gas connectionInlet: diameter 18.6mm Outlet: side outlet diameter 18.6 mm
Leakage requirementsAccording to EN126
Pressure valveTop for measuring inlet and outlet pressure
ScreenOn the input side
Softlite pressure5 mbar (-3.5/+0 after 1.5 sec.) adjustable

Choosing and fitting

When selecting a gas valve of this type, ensure the connection thread and diameter match the existing piping, and verify the maximum inlet and operating pressures are compatible with the system. The valve must be installed upright, and the electrical connections should match the ignition regulator, with exceptions for certain series. Check the ambient temperature range and pressure drop requirements to confirm suitability for the application.

Signs of failure

Common failures in gas valves of this kind include sticking or leaking valves, which can cause erratic flame behavior or failure to ignite. Symptoms may include the burner not starting, fluctuating gas pressure, or the system shutting down unexpectedly. Check for proper electrical connections, valve operation, and any blockages in the inlet filter.

All specifications

Max. inlet pressure60 mbar
Connection threadflanged
Regulation of the gas and air mixture in an ideal 11 ratio
Compression fitting4 mm
Ambient temperature-15–60 °C
Maximum inlet pressure60 mbar
Maximum operating pressure30 mbar
Inlet and outlet diameter18.6 mm
Back pressure (1st valve)50 mbar
Leakage requirementsen126
Ambient pressure1013 mbar
Input screenon the input side
Two electrical devicestwo electronic devices
Pressure drop3 mbar
Softlite time1.5 sec.
Ignition regulator exceptions4565/s4585 series
Pilot flowpresent
Flow capacity3.4 m³/h

Part numbers

SKUVK4100Q2003B
Additional article534.331.908
ModelVK4100Q2003