{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Honeywell Gas valve VK4105C1058U

SKU VK4105C1058U Model VK4105C1058 Brand Honeywell

Photos

Key specifications

Max. inlet pressure60 mbar
Connection threadflanged
Supply voltage220–240 V
Current consumption0.048 A
Voltage220–240 V
Outlet Orientationside outlet
Installation positionupright
Valve typegas valve
Operating principlepositive feedback system
Control featureselectric two-level control mechanism
Gas typeheating liquefied natural
Electrical connectionconnector or plug-in rectifier unit
Housing typestandard housing
Diaphragm diameter2.8 mm
Pilot gas connection diameter4 mm
Inlet and outlet diameter18.6 mm
Back pressure (1st valve)50 mbar
Leakage requirementsEN126
Nominal inlet gas pressure25 mbar
Pressure sensor pipe diameter0.5 inch
Operating positionupright
Ambient temperature-15–60 °C
Maximum inlet pressure60 mbar
Maximum operating pressure45 mbar
Max operating pressure45 mbar
Medium temperature20 C
Regulation of the mixture of gas and air in a ratio of 11
Softlite pressure3 mbar
Softlite technologysmooth ignition
Mounting featureholes for mounting
Ambient pressure1013 mbar
Built-in filterfine-mesh filter
Throttle valve regulationregulation via the throttle valve
Design featurespositive feedback system
Input screenon the input side
Performance curveh10
Pressure relief valvepressure relief valve
Filter cleaningnot intended for cleaning
Output pressure stabilitystable output pressure
Softlite time1.5 sec.
Strainer cleaningnot intended for cleaning
Pressure servo controllerpressure servo controller
Ignition regulator exceptions4565/s4585 series regulators
Flanged connectionsflanged connection
Filter typefine-mesh filter
Configurable optionsvariety of configuration options
Regulation of the gas and air mixture in an ideal 11 ratio
Frequency50 Hz
all specifications (48) ↓
113.14 EUR
102.85EUR
in stock · 120

incl. 21% VAT · 85.00 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Honeywell VK4105C1058U is a gas valve designed for burner control and ignition systems. It features a positive feedback system, electric two-level control, and Softlite technology for smooth ignition. The valve operates with heating liquefied natural gas, has a maximum inlet pressure of 60 mbar, and a nominal inlet pressure of 25 mbar. It includes a fine-mesh filter, pressure relief valve, and pressure servo controller, with flanged connections and a side outlet.

Further details

Back pressure1st valve: 50 mbar 2nd valve: 0 mbar
Closing Variantsb + c b + b b + j
Gas connectionInlet: diameter 18.6mm Outlet: side outlet diameter 18.6 mm
Gradual Adjustmentsmooth regulation with the possibility of adjustment for various control methods
Leakage requirementsAccording to EN126
Load1st + 2nd operator 48 mA at 220 V AC
Optional Output Filteradditional output filter can be installed
Performance (by air)3.4 miles/3 mbar thermal pressure drop
Performance curveH10
Pressure Measuring Fittingssilicone tubes with a diameter of 4 or 6 mm
Pressure Measuring Pointstop for measuring inlet and outlet pressure
Pressure valveTop for measuring inlet and outlet pressure
Ratings220 ... 240 V AC; 50 Hz
Safety Featureautomatic closing of the main valve in case of lack of power supply or excess gas pressure
ScreenOn the input side
Smooth Regulation With Amplificationsmooth regulation with the possibility of adjustment for various control methods
Softlite pressure3 mbar (-2/+0 after 1.5 sec.) adjustable
Standard Dbi Ignition Systemsplug-in rectifier unit for standard dbi ignition systems
Two Electrical Devicesprecise control of the main valve; constant monitoring of the valve position

Choosing and fitting

When selecting a gas valve of this type, ensure the connection thread, inlet/outlet diameters, and mounting orientation match the existing setup. Verify the supply voltage (220–240 V, 50 Hz) and current consumption (0.048 A) are compatible. Check the maximum operating pressure (45 mbar) and ambient temperature range (-15–60 °C) against system requirements. The valve must be installed upright with proper clearance for the side outlet and pilot gas connection.

Signs of failure

Common failures include sticking or leaking valves due to debris or wear, leading to unstable gas flow or failure to ignite. Symptoms may include burner not lighting, fluctuating flame, or gas odor. Check the fine-mesh filter for clogging (not cleanable) and inspect the pressure relief valve and servo controller for proper operation. Verify electrical connections and that the valve receives correct voltage.

All specifications

Max. inlet pressure60 mbar
Connection threadflanged
Supply voltage220–240 V
Current consumption0.048 A
Voltage220–240 V
Outlet Orientationside outlet
Installation positionupright
Valve typegas valve
Operating principlepositive feedback system
Control featureselectric two-level control mechanism
Gas typeheating liquefied natural
Electrical connectionconnector or plug-in rectifier unit
Housing typestandard housing
Diaphragm diameter2.8 mm
Pilot gas connection diameter4 mm
Inlet and outlet diameter18.6 mm
Back pressure (1st valve)50 mbar
Leakage requirementsEN126
Nominal inlet gas pressure25 mbar
Pressure sensor pipe diameter0.5 inch
Operating positionupright
Ambient temperature-15–60 °C
Maximum inlet pressure60 mbar
Maximum operating pressure45 mbar
Max operating pressure45 mbar
Medium temperature20 C
Regulation of the mixture of gas and air in a ratio of 11
Softlite pressure3 mbar
Softlite technologysmooth ignition
Mounting featureholes for mounting
Ambient pressure1013 mbar
Built-in filterfine-mesh filter
Throttle valve regulationregulation via the throttle valve
Design featurespositive feedback system
Input screenon the input side
Performance curveh10
Pressure relief valvepressure relief valve
Filter cleaningnot intended for cleaning
Output pressure stabilitystable output pressure
Softlite time1.5 sec.
Strainer cleaningnot intended for cleaning
Pressure servo controllerpressure servo controller
Ignition regulator exceptions4565/s4585 series regulators
Flanged connectionsflanged connection
Filter typefine-mesh filter
Configurable optionsvariety of configuration options
Regulation of the gas and air mixture in an ideal 11 ratio
Frequency50 Hz

Part numbers

SKUVK4105C1058U
Additional article534.331.905
ModelVK4105C1058