Honeywell Gas valve VK4105C1058U
SKU VK4105C1058U
Model VK4105C1058
Brand Honeywell
Photos
Key specifications
| Max. inlet pressure | 60 mbar |
|---|---|
| Connection thread | flanged |
| Supply voltage | 220–240 V |
| Current consumption | 0.048 A |
| Voltage | 220–240 V |
| Outlet Orientation | side outlet |
| Installation position | upright |
| Valve type | gas valve |
| Operating principle | positive feedback system |
| Control features | electric two-level control mechanism |
| Gas type | heating liquefied natural |
| Electrical connection | connector or plug-in rectifier unit |
| Housing type | standard housing |
| Diaphragm diameter | 2.8 mm |
| Pilot gas connection diameter | 4 mm |
| Inlet and outlet diameter | 18.6 mm |
| Back pressure (1st valve) | 50 mbar |
| Leakage requirements | EN126 |
| Nominal inlet gas pressure | 25 mbar |
| Pressure sensor pipe diameter | 0.5 inch |
| Operating position | upright |
| Ambient temperature | -15–60 °C |
| Maximum inlet pressure | 60 mbar |
| Maximum operating pressure | 45 mbar |
| Max operating pressure | 45 mbar |
| Medium temperature | 20 C |
| Regulation of the mixture of gas and air in a ratio of 1 | 1 |
| Softlite pressure | 3 mbar |
| Softlite technology | smooth ignition |
| Mounting feature | holes for mounting |
| Ambient pressure | 1013 mbar |
| Built-in filter | fine-mesh filter |
| Throttle valve regulation | regulation via the throttle valve |
| Design features | positive feedback system |
| Input screen | on the input side |
| Performance curve | h10 |
| Pressure relief valve | pressure relief valve |
| Filter cleaning | not intended for cleaning |
| Output pressure stability | stable output pressure |
| Softlite time | 1.5 sec. |
| Strainer cleaning | not intended for cleaning |
| Pressure servo controller | pressure servo controller |
| Ignition regulator exception | s4565/s4585 series regulators |
| Flanged connections | flanged connection |
| Filter type | fine-mesh filter |
| Configurable options | variety of configuration options |
| Regulation of the gas and air mixture in an ideal 1 | 1 ratio |
| Frequency | 50 Hz |
113.14 EUR
102.85EUR
in stock · 120
incl. 21% VAT · 85.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Honeywell VK4105C1058U is a gas valve designed for burner control and ignition systems. It features a positive feedback system, electric two-level control, and Softlite technology for smooth ignition. The valve operates with heating liquefied natural gas, has a maximum inlet pressure of 60 mbar, and a nominal inlet pressure of 25 mbar. It includes a fine-mesh filter, pressure relief valve, and pressure servo controller, with flanged connections and a side outlet.
Further details
| Back pressure | 1st valve: 50 mbar 2nd valve: 0 mbar |
|---|---|
| Closing Variants | b + c b + b b + j |
| Gas connection | Inlet: diameter 18.6mm Outlet: side outlet diameter 18.6 mm |
| Gradual Adjustment | smooth regulation with the possibility of adjustment for various control methods |
| Leakage requirements | According to EN126 |
| Load | 1st + 2nd operator 48 mA at 220 V AC |
| Optional Output Filter | additional output filter can be installed |
| Performance (by air) | 3.4 miles/3 mbar thermal pressure drop |
| Performance curve | H10 |
| Pressure Measuring Fittings | silicone tubes with a diameter of 4 or 6 mm |
| Pressure Measuring Points | top for measuring inlet and outlet pressure |
| Pressure valve | Top for measuring inlet and outlet pressure |
| Ratings | 220 ... 240 V AC; 50 Hz |
| Safety Feature | automatic closing of the main valve in case of lack of power supply or excess gas pressure |
| Screen | On the input side |
| Smooth Regulation With Amplification | smooth regulation with the possibility of adjustment for various control methods |
| Softlite pressure | 3 mbar (-2/+0 after 1.5 sec.) adjustable |
| Standard Dbi Ignition Systems | plug-in rectifier unit for standard dbi ignition systems |
| Two Electrical Devices | precise control of the main valve; constant monitoring of the valve position |
Choosing and fitting
When selecting a gas valve of this type, ensure the connection thread, inlet/outlet diameters, and mounting orientation match the existing setup. Verify the supply voltage (220–240 V, 50 Hz) and current consumption (0.048 A) are compatible. Check the maximum operating pressure (45 mbar) and ambient temperature range (-15–60 °C) against system requirements. The valve must be installed upright with proper clearance for the side outlet and pilot gas connection.
Signs of failure
Common failures include sticking or leaking valves due to debris or wear, leading to unstable gas flow or failure to ignite. Symptoms may include burner not lighting, fluctuating flame, or gas odor. Check the fine-mesh filter for clogging (not cleanable) and inspect the pressure relief valve and servo controller for proper operation. Verify electrical connections and that the valve receives correct voltage.
All specifications
| Max. inlet pressure | 60 mbar |
|---|---|
| Connection thread | flanged |
| Supply voltage | 220–240 V |
| Current consumption | 0.048 A |
| Voltage | 220–240 V |
| Outlet Orientation | side outlet |
| Installation position | upright |
| Valve type | gas valve |
| Operating principle | positive feedback system |
| Control features | electric two-level control mechanism |
| Gas type | heating liquefied natural |
| Electrical connection | connector or plug-in rectifier unit |
| Housing type | standard housing |
| Diaphragm diameter | 2.8 mm |
| Pilot gas connection diameter | 4 mm |
| Inlet and outlet diameter | 18.6 mm |
| Back pressure (1st valve) | 50 mbar |
| Leakage requirements | EN126 |
| Nominal inlet gas pressure | 25 mbar |
| Pressure sensor pipe diameter | 0.5 inch |
| Operating position | upright |
| Ambient temperature | -15–60 °C |
| Maximum inlet pressure | 60 mbar |
| Maximum operating pressure | 45 mbar |
| Max operating pressure | 45 mbar |
| Medium temperature | 20 C |
| Regulation of the mixture of gas and air in a ratio of 1 | 1 |
| Softlite pressure | 3 mbar |
| Softlite technology | smooth ignition |
| Mounting feature | holes for mounting |
| Ambient pressure | 1013 mbar |
| Built-in filter | fine-mesh filter |
| Throttle valve regulation | regulation via the throttle valve |
| Design features | positive feedback system |
| Input screen | on the input side |
| Performance curve | h10 |
| Pressure relief valve | pressure relief valve |
| Filter cleaning | not intended for cleaning |
| Output pressure stability | stable output pressure |
| Softlite time | 1.5 sec. |
| Strainer cleaning | not intended for cleaning |
| Pressure servo controller | pressure servo controller |
| Ignition regulator exception | s4565/s4585 series regulators |
| Flanged connections | flanged connection |
| Filter type | fine-mesh filter |
| Configurable options | variety of configuration options |
| Regulation of the gas and air mixture in an ideal 1 | 1 ratio |
| Frequency | 50 Hz |
Part numbers
| SKU | VK4105C1058U |
|---|---|
| Additional article | 534.331.905 |
| Model | VK4105C1058 |