Honeywell Gas solenoid valve VK4105G1138B
SKU VK4105G1138B
Model VK4105G1138
Brand Honeywell
Photos
Key specifications
| Max. inlet pressure | 60 mbar |
|---|---|
| Connection thread | 3/4" external |
| Ambient temperature | -15–60 °C |
| Maximum inlet pressure | 60 mbar |
| Maximum working pressure | 60 bar |
| Pilot gas connection diameter | 4 mm |
| Inlet and outlet diameter | 18.6 mm |
| Leakage requirements | according to en126 |
| Ambient pressure | 1013 mbar |
| Input screen | on the input side |
| Pressure drop | 3 mbar |
| Ignition regulator exception | s4565/s4585 series regulators |
| Flow capacity | 2.6 m³/h |
140.15 EUR
127.41EUR
in stock · 6
incl. 21% VAT · 105.30 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Honeywell VK4105G1138B is a gas solenoid valve designed for burner control and ignition systems, providing gas flow regulation for both pilot and main burners. It operates with an ambient temperature range of -15 to 60 °C and a maximum inlet pressure of 60 mbar. The valve features a 3/4" external connection thread and a flow capacity of 2.6 m³/h at a pressure drop of 3 mbar. It includes a pilot gas connection diameter of 4 mm and an inlet/outlet diameter of 18.6 mm. This model is compatible with BAXI MAIN Four 18 F, 24, and 240 F boilers.
Further details
| Back pressure | 1st valve: 50 mbar; 2nd valve: - |
|---|---|
| Capacity (by air) | 2.6 m3/h with a pressure drop of 3 mbar |
| Gas connection | Inlet: 3/4" External outlet: 3/4" external side outlet: - |
| Leakage requirements | According to EN126 |
| Optional Output Filter | additional output filter can be installed |
| Output Pressure Stability | stable output pressure even with changes in input pressure |
| Pressure Measuring Fittings | silicone tubes with a diameter of 4 or 6 mm |
| Pressure Measuring Points | top to measure inlet and outlet pressure |
| Pressure Relief Valve | high-tech pressure servo controller and a pressure relief valve |
| Pressure valve | Top to measure inlet and outlet pressure |
| Screen | On the input side |
| Standard Dbi Ignition Systems | plug-in rectifier unit for standard dbi ignition systems |
Choosing and fitting
Parts of this type are selected by matching the connection thread size, maximum inlet pressure, and flow capacity to the burner's requirements. The valve must be installed upright, and the inlet and outlet connections should be checked for compatibility with flanged or threaded fittings. Ensure the electrical connections match the ignition regulator specifications, excluding S4565/S4585 series regulators. Verify the ambient temperature and pressure conditions align with the valve's operational limits before installation.
Signs of failure
When gas solenoid valves of this kind fail, common symptoms include inconsistent flame control, failure to ignite, or gas flow interruptions. The equipment may exhibit pressure drops or unstable output pressure, leading to burner shutdowns. Check for blockages in the inlet filter, electrical connection issues, or mechanical wear in the valve mechanism. Leakage may occur, so inspect for gas odors and test according to EN126 standards.
Fits equipment
BAXI MAIN Four 18 F, 24, 240 F
All specifications
| Max. inlet pressure | 60 mbar |
|---|---|
| Connection thread | 3/4" external |
| Ambient temperature | -15–60 °C |
| Maximum inlet pressure | 60 mbar |
| Maximum working pressure | 60 bar |
| Pilot gas connection diameter | 4 mm |
| Inlet and outlet diameter | 18.6 mm |
| Leakage requirements | according to en126 |
| Ambient pressure | 1013 mbar |
| Input screen | on the input side |
| Pressure drop | 3 mbar |
| Ignition regulator exception | s4565/s4585 series regulators |
| Flow capacity | 2.6 m³/h |
Part numbers
| SKU | VK4105G1138B |
|---|---|
| Additional article | 534.331.704 |
| Model | VK4105G1138 |
| Superseded number | 5702340 |