Honeywell Gas valve VK4125P2001U
SKU VK4125P2001U
Model VK4125P2001
Brand Honeywell
Photos
Key specifications
| Max. inlet pressure | 60 mbar |
|---|---|
| Connection thread | 1/2" BSP.PL |
| Supply voltage | 220–240 V |
| Outlet Orientation | side gas outlet |
| Current consumption | 48 A |
| Voltage | 220–240 V |
| Valve type | gas solenoid valve |
| Operating principle | positive feedback system |
| Control features | electric two-level regulator |
| Electrical connection | connector or plug-in rectifier unit |
| Operating voltage | 24 |
| Housing type | standard |
| Diaphragm diameter | 2.8 mm |
| Pilot gas connection diameter | 4 mm |
| Inlet and outlet diameter | 18.6 mm |
| Leakage requirements | EN126 |
| Nominal inlet gas pressure | 25 mbar |
| Pressure sensor pipe diameter | 0.5 inch |
| Operating position | vertical |
| Ambient temperature | -15–60 °C |
| Maximum inlet pressure | 60 mbar |
| Maximum operating pressure | 30 mbar |
| Catalogue article numbers | 534.322.264 |
| Regulation of the mixture of gas and air in a ratio of 1 | 1 |
| Softlite technology | Softlite system |
| Mounting feature | holes at the bottom |
| Ambient pressure | 1013 mbar |
| Built-in filter | fine-mesh filter |
| Optional output filter | available |
| Throttle valve regulation | option |
| Design features | positive feedback system |
| Input screen | input side |
| Performance curve | H30 |
| Two electrical devices | two electrical devices |
| Ignition systems supported | DBI |
| Power options | 24V option |
| Flow indication | cubic meters per hour |
| Pressure drop | 5 mbar |
| Flange collector required | required for side outlet |
| Pressure relief valve | present |
| Filter cleaning | not intended for cleaning |
| Side socket | side gas outlet |
| Output pressure stability | stable output pressure |
| Strainer cleaning | not intended for cleaning |
| Control type | servo drive pressure regulation |
| connection_type | flanged |
| Back pressure (1st valve) | 50 mbar |
| Smooth regulation with amplification | available |
| Frequency | 50 Hz |
404.80 EUR
368.00EUR
in stock · 1
incl. 21% VAT · 304.13 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The VK4125P2001U is a gas solenoid valve with a standard housing and a side gas outlet. It operates at 220–240 V, 50 Hz, and uses a positive feedback system with servo drive pressure regulation and a pressure relief valve to maintain stable output pressure. It features an electric two-level regulator and supports the Softlite system. The valve has a built-in fine-mesh filter, a 4 mm pilot gas connection, and flanged connections. It meets leakage requirements per EN126, has a nominal inlet pressure of 25 mbar, a maximum inlet pressure of 60 mbar, a maximum operating pressure of 30 mbar, and an ambient temperature range of -15–60 °C.
Further details
| Closing Variants | b + j, b + c, b + b |
|---|---|
| Electrical devices | two electrical devices: one for controlling the main valve and the other for controlling its position |
| Gas Type | heating gas, natural gas and liquefied gas |
| Ignition Electronics Compatibility | 24V for joint use with other ignition regulators, excluding s4565/s4585 |
| Included Components | vk4125 p 2001b gas regulator and special ignition regulator |
| Measurement setup | sensor on 1/2-inch pipe, 10x diameter, short hose length 5 pipe diameters |
| Pressure Measuring Fittings | silicone tubes 4 or 6 mm |
| Pressure Measuring Points | top pressure valve for inlet/outlet pressure |
| Pressure test points | top for measuring inlet and outlet pressure |
| Safety Feature | main valve automatically closes when there is no power supply or gas pressure is exceeded |
Choosing and fitting
Gas valves of this type are selected by verifying the gas outlet orientation: a side outlet requires a flanged burner manifold. Check the electrical connection type, either a connector or a plug-in rectifier unit, and confirm whether a 24 V option is needed; the 24 V option is not compatible with S4565/S4585 regulators. Mounting holes are at the bottom, and variants may have different closing-force ratings such as B+J, B+C, or B+B. Optional features such as throttle-valve regulation should also be confirmed before ordering.
All specifications
| Max. inlet pressure | 60 mbar |
|---|---|
| Connection thread | 1/2" BSP.PL |
| Supply voltage | 220–240 V |
| Outlet Orientation | side gas outlet |
| Current consumption | 48 A |
| Voltage | 220–240 V |
| Valve type | gas solenoid valve |
| Operating principle | positive feedback system |
| Control features | electric two-level regulator |
| Electrical connection | connector or plug-in rectifier unit |
| Operating voltage | 24 |
| Housing type | standard |
| Diaphragm diameter | 2.8 mm |
| Pilot gas connection diameter | 4 mm |
| Inlet and outlet diameter | 18.6 mm |
| Leakage requirements | EN126 |
| Nominal inlet gas pressure | 25 mbar |
| Pressure sensor pipe diameter | 0.5 inch |
| Operating position | vertical |
| Ambient temperature | -15–60 °C |
| Maximum inlet pressure | 60 mbar |
| Maximum operating pressure | 30 mbar |
| Catalogue article numbers | 534.322.264 |
| Regulation of the mixture of gas and air in a ratio of 1 | 1 |
| Softlite technology | Softlite system |
| Mounting feature | holes at the bottom |
| Ambient pressure | 1013 mbar |
| Built-in filter | fine-mesh filter |
| Optional output filter | available |
| Throttle valve regulation | option |
| Design features | positive feedback system |
| Input screen | input side |
| Performance curve | H30 |
| Two electrical devices | two electrical devices |
| Ignition systems supported | DBI |
| Power options | 24V option |
| Flow indication | cubic meters per hour |
| Pressure drop | 5 mbar |
| Flange collector required | required for side outlet |
| Pressure relief valve | present |
| Filter cleaning | not intended for cleaning |
| Side socket | side gas outlet |
| Output pressure stability | stable output pressure |
| Strainer cleaning | not intended for cleaning |
| Control type | servo drive pressure regulation |
| connection_type | flanged |
| Back pressure (1st valve) | 50 mbar |
| Smooth regulation with amplification | available |
| Frequency | 50 Hz |
Part numbers
| SKU | VK4125P2001U |
|---|---|
| Additional article | 534.322.264 |
| Model | VK4125P2001 |