Honeywell Gas valve VR4601CB1073B
SKU VR4601CB1073B
Model VR4601CB1073
Brand Honeywell
Photos
Key specifications
| Max. inlet pressure | 60 mbar |
|---|---|
| Connection thread | flanged |
| Diaphragm diameter | 2.8 mm |
| Inlet and outlet diameter | 23 mm |
| Back pressure (1st valve) | 50 mbar |
| Leakage requirements | EN 126 |
| Nominal inlet gas pressure | 25 mbar |
| Maximum inlet pressure | 60 mbar |
| Maximum operating pressure | 45 mbar |
| Max operating pressure | 45 mbar |
| Softlite pressure | 7 mbar |
| Ambient pressure | 1013 mbar |
| Pressure drop | 3 mbar |
| Softlite time | 1.5 sec. |
| Output aperture diameter | 2.8 mm |
| Flow capacity | 4.2 m³/h |
| Certification | CE |
360.17 EUR
327.43EUR
in stock · 1
incl. 21% VAT · 270.60 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Honeywell VR4601CB1073B is a compact automatic gas solenoid valve designed for gas flow control in home heating systems, boilers, and water heaters. It features a flanged connection with inlet and outlet diameters of 23 mm, and operates with a maximum inlet pressure of 60 mbar and a nominal inlet pressure of 25 mbar. The valve has a flow capacity of 4.2 m³/h at a pressure drop of 3 mbar, and includes a softlite pressure of 7 mbar with a softlite time of 1.5 seconds. It is certified to CE standards and meets leakage requirements according to EN 126.
Choosing and fitting
When selecting a gas valve of this type, ensure the connection type (flanged) and inlet/outlet diameters match the existing piping. Verify the maximum inlet pressure and operating pressure ratings are compatible with your system's supply pressure. Check the flow capacity to ensure it meets the burner's demand. The valve's mounting orientation can be adjusted within 90 degrees from vertical, and it has two threaded mounting holes for installation.
Signs of failure
Common failure modes for gas valves of this kind include sticking or leaking due to debris or wear, leading to improper gas flow or failure to close. Symptoms may include burner ignition issues, fluctuating flame, or gas odor. Check for proper electrical connection to the actuators, inspect the inlet screen for blockage, and test for leaks using appropriate methods.
All specifications
| Max. inlet pressure | 60 mbar |
|---|---|
| Connection thread | flanged |
| Diaphragm diameter | 2.8 mm |
| Inlet and outlet diameter | 23 mm |
| Back pressure (1st valve) | 50 mbar |
| Leakage requirements | EN 126 |
| Nominal inlet gas pressure | 25 mbar |
| Maximum inlet pressure | 60 mbar |
| Maximum operating pressure | 45 mbar |
| Max operating pressure | 45 mbar |
| Softlite pressure | 7 mbar |
| Ambient pressure | 1013 mbar |
| Pressure drop | 3 mbar |
| Softlite time | 1.5 sec. |
| Output aperture diameter | 2.8 mm |
| Flow capacity | 4.2 m³/h |
| Certification | CE |
Part numbers
| SKU | VR4601CB1073B |
|---|---|
| Additional article | 534.322.230 |
| Model | VR4601CB1073 |