{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Honeywell Gas solenoid valves VR4601QB2001U

SKU VR4601QB2001U Model VR4601QB2001 Brand Honeywell

Photos

Key specifications

Nominal diameter (DN)23 mm
Max. inlet pressure60 mbar
Maximum inlet pressure60 mbar
Maximum operating pressure30 mbar
Output aperture diameter2.8 mm
Ambient pressure1013 mbar
Softlite pressure5 mbar
Back pressure (1st valve)50 mbar
Pressure drop3 mbar
Flow capacity4.2 m³/h
all specifications (10) ↓
344.18 EUR
312.89EUR
in stock · 6

incl. 21% VAT · 258.59 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Honeywell VR4601QB2001U is a gas solenoid valve designed for safe regulation of gas flow in domestic heating systems, boilers, and water heaters. It has a nominal diameter of 23 mm, a maximum inlet pressure of 60 mbar, and a maximum operating pressure of 30 mbar. The valve provides a flow capacity of 4.2 m³/h at a pressure drop of 3 mbar, with an output aperture of 2.8 mm. It is suitable for use with Mora VI7690 (7690) boilers.

Choosing and fitting

Parts of this type are selected by matching the nominal diameter, maximum inlet pressure, and flow capacity to the system requirements. Installation involves ensuring the valve's inlet and outlet connections align with the existing piping, and that the electrical connections match the system's voltage and control signals. The valve can be mounted in any orientation within 90 degrees from vertical, and it includes threaded mounting holes for secure attachment.

Signs of failure

Common failure modes for gas valves of this kind include sticking or leaking due to debris or wear, leading to improper gas flow or failure to close. Symptoms may include the burner not igniting, fluctuating flame, or gas odor. Check for proper voltage at the valve terminals, inspect the inlet filter for blockage, and test for leaks around the valve body and connections.

Fits equipment

MORA VI7690 (7690)

All specifications

Nominal diameter (DN)23 mm
Max. inlet pressure60 mbar
Maximum inlet pressure60 mbar
Maximum operating pressure30 mbar
Output aperture diameter2.8 mm
Ambient pressure1013 mbar
Softlite pressure5 mbar
Back pressure (1st valve)50 mbar
Pressure drop3 mbar
Flow capacity4.2 m³/h

Part numbers

SKUVR4601QB2001U
Additional article534.322.010
ModelVR4601QB2001