Honeywell Gas solenoid valve VR4605A1062B

SKU VR4605A1062B Model VR4605A1062 Brand Honeywell

Photos

Key specifications

Connection thread1/2" BSP.PL (inlet/outlet)
Valve typeGas solenoid valve
Leakage requirementsEN 126
Pressure drop3 mbar
Output aperture diameter2.8 mm
Maximum inlet pressure100 mbar
Maximum operating pressure100 mbar
Back pressure (1st valve)50 mbar
Pressure sensor pipe diameter0.5 inch
Ignition systems supportedDSI, HSI, IP
Valve closing force variantsB+B, B+J, B+C, A+J, A+C
Design featuresPositive feedback system
Flow capacity3.1 m³/h
CertificationCE
all specifications (14) ↓
319.44 EUR
290.40EUR
in stock · 1

incl. 21% VAT · 240.00 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

This gas solenoid valve (model VR4605A1062, SKU VR4605A1062B) is equipped with 1/2" BSP.PL threads at both inlet and outlet. It is CE certified and complies with EN 126 leakage requirements. With an output aperture of 2.8 mm, it achieves a flow capacity of 3.1 m³/h at a pressure drop of 3 mbar. Maximum inlet and operating pressure is 100 mbar, while the first valve back pressure is 50 mbar; the pressure sensor pipe diameter is 0.5 inch. The valve supports DSI, HSI, and IP ignition systems and features a positive feedback system, with closing variants B+B, B+J, B+C, A+J, A+C.

Further details

Actuator TypeTwo-position tracking actuator for the main valve
ApplicationHome heating systems, radiators, boilers and water heaters
Back pressure of the 1st valve50 mbar; 2nd valve: -
Built In FilterInternal fine-mesh filter on input side
Control FeaturesPressure adjustment, throttle valves, soft ignition devices, two-level control, gas flow modulation
Electrical ConnectionElectrical connector per DIN standard; compatible with AMP connectors
Gas TypePetroleum gas MFD group A (G110), group B (G120), natural gas H (G20), natural gas L (G25), liquefied gas LP (G30)
Gas connection input1/2" BSP.Pl Outlet hole: 1/2"BSP.Pl
Mounting FeatureTwo threaded mounting holes at the base for mounting on the heating system
Operating PrincipleAutomatic control of the gas outlet pressure
Optional Output FilterOutput mesh filter available on request
Output Pressure StabilityStable outlet pressure regardless of changes in inlet pressure
Pressure Test PointsPressure measuring fittings with outer diameter 9 mm on input and output sides
Regulator Spring LockRegulator spring can be locked when pressure regulation is not required
Safety FeatureMain valve closes in case of a power failure or gas supply interruption
Two Electrical DevicesTwo electrical actuators: safety-valve actuator and main-valve actuator

Choosing and fitting

For a replacement gas solenoid valve of this type, match the pipe connection thread (usually BSP.PL) and note whether the gas family, maximum inlet pressure, and flow capacity are adequate for the installation. The closing class combination (shown as pairs of letters such as B+B or A+C) and the actuator power supply must be the same as on the original. Install the regulator with the actuator vertical or within 90° of that position; secure it to the system using the two threaded mounting holes at its base. Pressure measuring fittings are provided on the inlet and outlet sides for checking burner pressure.

All specifications

Connection thread1/2" BSP.PL (inlet/outlet)
Valve typeGas solenoid valve
Leakage requirementsEN 126
Pressure drop3 mbar
Output aperture diameter2.8 mm
Maximum inlet pressure100 mbar
Maximum operating pressure100 mbar
Back pressure (1st valve)50 mbar
Pressure sensor pipe diameter0.5 inch
Ignition systems supportedDSI, HSI, IP
Valve closing force variantsB+B, B+J, B+C, A+J, A+C
Design featuresPositive feedback system
Flow capacity3.1 m³/h
CertificationCE

Part numbers

SKUVR4605A1062B
Additional article534.322.119
ModelVR4605A1062