{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Honeywell Gas solenoid valve VR4605CB1025U

SKU VR4605CB1025U Model VR4605CB1025 Brand Honeywell

Photos

Key specifications

Max. inlet pressure60 mbar
Connection threadcompression fitting
Coil connectiontop connection
Pressure drop3 mbar
Output aperture diameter2.8 mm
Filter typeinternal fine-mesh filter
Operator part numberv404a 1329 (45.801.130-001)
Flow capacity4.2 m³/h
CertificationCE
all specifications (9) ↓
355.77 EUR
323.43EUR
in stock · 2

incl. 21% VAT · 267.30 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Honeywell VR4605CB1025U is a gas solenoid valve designed for gas flow control in domestic heating systems, boilers, and water heaters. It features a compression fitting connection, a maximum inlet pressure of 60 mbar, and a flow capacity of 4.2 m³/h at a pressure drop of 3 mbar. The valve includes an internal fine-mesh filter and has a 2.8 mm output aperture. It is CE certified and uses a top connection for the coil, with operator part number v404a 1329 (45.801.130-001).

Choosing and fitting

When selecting a replacement gas valve of this type, ensure the connection thread type and size match the existing piping, as well as the maximum inlet pressure and flow capacity requirements. The coil connection orientation (top, side, or bottom) must align with the available space and wiring. Verify the operator part number to ensure compatibility with the burner control system. Installation should follow manufacturer guidelines, including proper mounting orientation and torque specifications.

Signs of failure

Common failures in gas valves of this kind include coil burnout, which prevents the valve from opening, leading to no gas flow and the burner not igniting. Diaphragm or seal degradation can cause internal leaks, resulting in pressure fluctuations or gas odor. A clogged internal filter may restrict flow, causing reduced burner output or intermittent operation. If the valve fails to close, it can lead to overpressure or unsafe conditions, often indicated by abnormal burner behavior or error codes on the control system.

All specifications

Max. inlet pressure60 mbar
Connection threadcompression fitting
Coil connectiontop connection
Pressure drop3 mbar
Output aperture diameter2.8 mm
Filter typeinternal fine-mesh filter
Operator part numberv404a 1329 (45.801.130-001)
Flow capacity4.2 m³/h
CertificationCE

Part numbers

SKUVR4605CB1025U
Additional article534.322.149
ModelVR4605CB1025