Honeywell Gas valve VR4605DB1008U

SKU VR4605DB1008U Model VR4605DB1008 Brand Honeywell

Photos

Key specifications

Max. inlet pressure60 mbar
Connection threadflanged
Certification standardEN 161
Back pressure (1st valve)50 mbar
Leakage requirementsEN 126
Nominal inlet gas pressure25 mbar
Pressure sensor pipe diameter0.5 inch
Maximum inlet pressure60 mbar
Maximum operating pressure60 mbar
Softlite pressure10 mbar
Ambient pressure1013 mbar
Optional output filteroutput mesh filter
Coil connectiontop connection
Pressure drop3 mbar
Pilot flowpresent
Flow capacity4.2 m³/h
CertificationCE
all specifications (17) ↓
355.77 EUR
323.43EUR
in stock · 2

incl. 21% VAT · 267.30 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Honeywell VR4605DB1008U is a gas valve with flanged connections, designed for use in gas-fired heating systems. It has a maximum inlet pressure of 60 mbar and a nominal inlet pressure of 25 mbar, with a flow capacity of 4.2 m³/h at a pressure drop of 3 mbar. The valve is CE certified to EN 161 and meets leakage requirements per EN 126. It features a top-connected coil and a pressure sensor pipe diameter of 0.5 inch, with an optional output mesh filter available.

Further details

Closing Variantsb + c, b + b, b + j
Operating Principleautomatic control of the gas outlet pressure

Choosing and fitting

When selecting a replacement gas valve of this type, ensure the connection type (flanged) and dimensions match the existing piping. Verify the maximum inlet pressure and flow capacity meet the system requirements. The valve must be compatible with the gas type and the control voltage of the system. Check the pressure sensor pipe diameter and the presence of a pilot flow if required.

Signs of failure

Common failures include the valve failing to open or close, leading to no gas flow or gas not shutting off. This may cause the burner to not ignite or to continue running after the call for heat ends. Check for proper electrical continuity across the coil and ensure the inlet pressure is within the specified range. Leaks may occur at the flanged connections or through the valve seat, detectable by gas odor or soap solution test.

All specifications

Max. inlet pressure60 mbar
Connection threadflanged
Certification standardEN 161
Back pressure (1st valve)50 mbar
Leakage requirementsEN 126
Nominal inlet gas pressure25 mbar
Pressure sensor pipe diameter0.5 inch
Maximum inlet pressure60 mbar
Maximum operating pressure60 mbar
Softlite pressure10 mbar
Ambient pressure1013 mbar
Optional output filteroutput mesh filter
Coil connectiontop connection
Pressure drop3 mbar
Pilot flowpresent
Flow capacity4.2 m³/h
CertificationCE

Part numbers

SKUVR4605DB1008U
Additional article534.322.015
ModelVR4605DB1008