Key specifications
| Max. inlet pressure | 60 mbar |
|---|---|
| Connection thread | flanged |
| Certification standard | EN 161 |
| Back pressure (1st valve) | 50 mbar |
| Leakage requirements | EN 126 |
| Nominal inlet gas pressure | 25 mbar |
| Pressure sensor pipe diameter | 0.5 inch |
| Maximum inlet pressure | 60 mbar |
| Maximum operating pressure | 60 mbar |
| Softlite pressure | 10 mbar |
| Ambient pressure | 1013 mbar |
| Optional output filter | output mesh filter |
| Coil connection | top connection |
| Pressure drop | 3 mbar |
| Pilot flow | present |
| Flow capacity | 4.2 m³/h |
| Certification | CE |
355.77 EUR
323.43EUR
in stock · 2
incl. 21% VAT · 267.30 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Honeywell VR4605DB1008U is a gas valve with flanged connections, designed for use in gas-fired heating systems. It has a maximum inlet pressure of 60 mbar and a nominal inlet pressure of 25 mbar, with a flow capacity of 4.2 m³/h at a pressure drop of 3 mbar. The valve is CE certified to EN 161 and meets leakage requirements per EN 126. It features a top-connected coil and a pressure sensor pipe diameter of 0.5 inch, with an optional output mesh filter available.
Further details
| Closing Variants | b + c, b + b, b + j |
|---|---|
| Operating Principle | automatic control of the gas outlet pressure |
Choosing and fitting
When selecting a replacement gas valve of this type, ensure the connection type (flanged) and dimensions match the existing piping. Verify the maximum inlet pressure and flow capacity meet the system requirements. The valve must be compatible with the gas type and the control voltage of the system. Check the pressure sensor pipe diameter and the presence of a pilot flow if required.
Signs of failure
Common failures include the valve failing to open or close, leading to no gas flow or gas not shutting off. This may cause the burner to not ignite or to continue running after the call for heat ends. Check for proper electrical continuity across the coil and ensure the inlet pressure is within the specified range. Leaks may occur at the flanged connections or through the valve seat, detectable by gas odor or soap solution test.
All specifications
| Max. inlet pressure | 60 mbar |
|---|---|
| Connection thread | flanged |
| Certification standard | EN 161 |
| Back pressure (1st valve) | 50 mbar |
| Leakage requirements | EN 126 |
| Nominal inlet gas pressure | 25 mbar |
| Pressure sensor pipe diameter | 0.5 inch |
| Maximum inlet pressure | 60 mbar |
| Maximum operating pressure | 60 mbar |
| Softlite pressure | 10 mbar |
| Ambient pressure | 1013 mbar |
| Optional output filter | output mesh filter |
| Coil connection | top connection |
| Pressure drop | 3 mbar |
| Pilot flow | present |
| Flow capacity | 4.2 m³/h |
| Certification | CE |
Part numbers
| SKU | VR4605DB1008U |
|---|---|
| Additional article | 534.322.015 |
| Model | VR4605DB1008 |