Kromschroder Solenoid gas valve VAS125R/NK 88000612
SKU 88000612
Model VAS125R/NK
Brand Kromschroder
Photos
Key specifications
| Nominal diameter (DN) | 25 mm |
|---|---|
| Max. inlet pressure | 500 mbar |
| Connection thread | Rp 1" |
| Supply voltage | 24 V |
| Weight | 1.603 g |
| Electrical connection | plug with socket |
| Valve size | 1 |
| Pipeline diameter range | DN 10 to DN 65 |
| Flanged connections | DN 40 and DN 50 |
| Net weight | 1.603 kg |
| Certification | EU certified |
—price on request
on order
shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Kromschroder Solenoid gas valve VAS125R/NK (SKU 88000612) is a normally closed, electrically operated gas valve with a nominal diameter of 25 mm and a connection thread of Rp 1". It operates with a supply voltage of 24 V DC and has a maximum inlet pressure of 500 mbar. The valve is EU certified and features a plug with socket electrical connection. Its net weight is 1.603 kg. This valve is designed for use in gas control systems for industrial applications such as metallurgy, glass, ceramics, public utilities, and food production.
Further details
| Accessories, left | 2 screw plugs |
|---|---|
| Accessories, right | 2 screw plugs |
| Adjustment Method | quick opening, quick closing with flow adjustment |
| Application | metallurgy, glass, ceramics, public utilities, food production |
| Auxiliary Devices | right: 2 screw plugs; left: 2 screw plugs |
| Electrical connection | plug with socket |
| Inlet | DN 25 (1'') |
| Mains voltage | 24 V DC |
| Outlet | DN 25 (1'') |
Choosing and fitting
When selecting a solenoid gas valve of this type, ensure the nominal diameter and connection thread match the existing pipeline. The valve size (e.g., size 1) and the pipeline diameter range (DN 10 to DN 65) must be compatible. For flanged connections, verify that the valve size corresponds to the required pipeline diameter (e.g., DN 40 or DN 50 for sizes 2 and 3). Also, confirm the supply voltage and electrical connection type match the system's control circuit. Installation should be performed by a qualified technician, following the manufacturer's guidelines for proper orientation and torque.
Signs of failure
Common failure modes for solenoid gas valves include coil burnout, which prevents the valve from opening, or debris blocking the valve seat, causing incomplete closure or leakage. Symptoms may include the burner failing to ignite, irregular flame, or gas odor. Check the electrical supply to the coil, inspect the valve for physical damage, and verify that the inlet pressure is within the specified range. If the valve does not open or close properly, it may need to be replaced.
All specifications
| Nominal diameter (DN) | 25 mm |
|---|---|
| Max. inlet pressure | 500 mbar |
| Connection thread | Rp 1" |
| Supply voltage | 24 V |
| Weight | 1.603 g |
| Electrical connection | plug with socket |
| Valve size | 1 |
| Pipeline diameter range | DN 10 to DN 65 |
| Flanged connections | DN 40 and DN 50 |
| Net weight | 1.603 kg |
| Certification | EU certified |
Part numbers
| SKU | 88000612 |
|---|---|
| Additional article | 624.337.138 |
| Model | VAS125R/NK |