Kromschroder Solenoid gas valve VAS110R/NW 88000002

SKU 88000002 Model VAS110R/NW Brand Kromschroder

Photos

Key specifications

Nominal diameter (DN)dn 10 to dn 65
Weight1561 g
connection_typethreaded flanges
Closing time1 s
Electrical connectionm20 cable gland
Opening timequick opening
Flow adjustmentwith flow adjustment
Normally closednormally closed
Safety standardsil and pl standards
Coil voltage230 V
Maximum pressure0.5 bar
Accessories left2 screw plugs
Accessories right2 screw plugs
Inlet connectiondn 10 (3/8'')
Flange size2 and 3
Suitable pipe DNdn 40 and dn 50
Thread typerp internal thread
Dual seat designdual-seat design
Gas appliance directive2009/142/ec
Standard EN 13611en 161
LED colorblue
Voltage limiterrectifier with a voltage limiter
Valve opening conditionwhen alternating voltage is applied
Valve closing conditionwhen power is removed
LED off conditionblue led goes out
all specifications (25) ↓
685.20 EUR
622.91EUR
in stock · 1

incl. 21% VAT · 514.80 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Kromschroder Solenoid gas valve VAS110R/NW (SKU 88000002) is a normally closed, dual-seat design valve with a coil voltage of 230 V. It features threaded flanges with an inlet connection of DN 10 (3/8'') and is suitable for pipelines with nominal diameters from DN 10 to DN 65. The valve has a maximum pressure of 0.5 bar, a closing time of 1 second, and quick opening with flow adjustment. It includes a blue LED indicator and is equipped with 2 screw plugs on both left and right accessories. The valve operates when alternating voltage is applied, and closes when power is removed, with the blue LED going out.

Further details

Accessories, left2 screw plugs
Accessories, right2 screw plugs
Closing springspring returns the stem to its original position
Electrical connectionM20 cable gland
Functionautomatic shut-off and regulating device for gas and air supply
InletDN 10 (3/8'')
Inlet screenprevents dirt particles from accumulating on the seats
Mains voltage230 V AC, 50/60 Hz
OutletDN 10 (3/8'')
Performance Levelpl e pursuant to iso 13849
Pressure distributioninlet pressure is distributed evenly across both seats
Pressure lossminimal pressure loss across the screen
Safety Integrity Levelsil 3 pursuant to en 61508
Suitable equipmentgas burners and other gas-consuming equipment
Suitable industriesmetallurgy, glassmaking, ceramics, public utilities, food production
Valve stem movementpulls the valve plate stem upward

Choosing and fitting

Parts of this type are selected by matching the coil voltage, connection type, and nominal diameter to the existing system. The flange size (2 or 3) must correspond to the pipe DN (40 or 50). The electrical connection is via an M20 cable gland, and the thread type is Rp internal. Ensure the maximum pressure rating (0.5 bar) is not exceeded. Installation involves connecting the threaded flanges and wiring the coil to the appropriate voltage source.

Signs of failure

Common failures include coil burnout, which prevents the valve from opening, and debris accumulation on the seats, causing leakage or slow closing. If the valve fails to open, check the coil voltage and the rectifier with voltage limiter. If it fails to close within 1 second, inspect the spring and seats for wear or contamination. The blue LED not lighting up indicates a power or coil issue.

All specifications

Nominal diameter (DN)dn 10 to dn 65
Weight1561 g
connection_typethreaded flanges
Closing time1 s
Electrical connectionm20 cable gland
Opening timequick opening
Flow adjustmentwith flow adjustment
Normally closednormally closed
Safety standardsil and pl standards
Coil voltage230 V
Maximum pressure0.5 bar
Accessories left2 screw plugs
Accessories right2 screw plugs
Inlet connectiondn 10 (3/8'')
Flange size2 and 3
Suitable pipe DNdn 40 and dn 50
Thread typerp internal thread
Dual seat designdual-seat design
Gas appliance directive2009/142/ec
Standard EN 13611en 161
LED colorblue
Voltage limiterrectifier with a voltage limiter
Valve opening conditionwhen alternating voltage is applied
Valve closing conditionwhen power is removed
LED off conditionblue led goes out

Part numbers

SKU88000002
Additional article624.337.132
ModelVAS110R/NW