Brahma High-voltage wire D5 PC64R4/P C00700344
SKU C00700344
Model D5 PC64R4/P
Brand Brahma
Photos
Key specifications
| Cable length | 1000 mm |
|---|---|
| Length | 1045 mm |
| Width | 32 mm |
| Height | 14 mm |
| suitable_for_fuel_types | gas and liquid fuel |
| Mechanical durability | resistant to mechanical loads |
| Component type | ignition cable |
| Heat resistance | resistant to high temperatures |
| Supplied as | complete assembly |
| Wear resistance | resistant to wear |
| insulation_material | silicone |
| cable_type | sil. cable d5 pc64r4/p |
| connector_pattern | d5 pc64r4/p |
| Net weight | 0.043 kg |
| Country of origin | Italy |
19.97 EUR
18.15EUR
in stock · 2
incl. 21% VAT · 15.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
This ignition cable is designed to transmit the high-voltage pulse from an ignition transformer to the spark electrode in automatic ignition systems for gas and liquid fuel burners. It is supplied as a complete assembly with a cable length of 1000 mm and an overall length of 1045 mm, width of 32 mm, and height of 14 mm, weighing 0.043 kg. The silicone insulation provides resistance to high temperatures, mechanical loads, and wear. The connector pattern is D5 PC64R4/P. This component is manufactured in Italy.
Further details
| Application | boiler equipment, industrial burners, and ignition systems |
|---|---|
| Failure mode warning | Hardened, cracked, or moisture-damaged cable can allow spark to leak to earth |
| Inspection requirement | Inspect the cable path for sharp edges or hot surfaces that could accelerate wear |
| Mechanical Durability | resistant to mechanical loads and wear |
| Replacement consideration | Replace without reusing the terminals when signs of tracking appear |
Choosing and fitting
Ignition cables of this type are selected by matching the connector pattern at both ends to the transformer output terminal and the electrode terminal, as well as by cable length and insulation rating. The connector pattern must match exactly; forcing an incorrect connector can damage the terminal or cause intermittent contact. The silicone insulation should be intact and flexible; any stiffness or cracking indicates ageing and potential leakage. Always inspect the cable path for sharp edges or hot surfaces that could accelerate wear.
Signs of failure
Ignition cables of this kind can fail due to hardening, cracking, or moisture damage, which allows the spark to leak to earth and mimics a faulty transformer, preventing ignition. Stiffness or cracking indicates ageing and potential leakage. Visible black carbon traces (tracking) on the surface are a sign of failure; the cable should be replaced completely, and the terminals should not be reused.
All specifications
| Cable length | 1000 mm |
|---|---|
| Length | 1045 mm |
| Width | 32 mm |
| Height | 14 mm |
| suitable_for_fuel_types | gas and liquid fuel |
| Mechanical durability | resistant to mechanical loads |
| Component type | ignition cable |
| Heat resistance | resistant to high temperatures |
| Supplied as | complete assembly |
| Wear resistance | resistant to wear |
| insulation_material | silicone |
| cable_type | sil. cable d5 pc64r4/p |
| connector_pattern | d5 pc64r4/p |
| Net weight | 0.043 kg |
| Country of origin | Italy |
Part numbers
| SKU | C00700344 |
|---|---|
| Additional article | 246.616.014 |
| Model | D5 PC64R4/P |