Description

The Cofi Ignition cable BV1 09CA036109 is a replacement part for the high-voltage connection between the ignition transformer and the ignition electrode in a burner. It is silicone-insulated to withstand the voltage produced by the transformer and the heat near the combustion head. The cable transfers the secondary voltage that generates the spark at the electrode gap. It is compatible with Master 4110.971 models BV100, BV160, BV280, BV110, BV170, BV290, B230, and B360 up to 2010.

Further details

Compatibility verificationverify end fittings and overall length against original
Compatible burnersMaster 4110.971 BV100, BV160, BV280, BV110, BV170, BV290, B230, B360 until 2010
Inspection requirementinspect connector boots and terminal contacts for corrosion or looseness
Replacement part forhigh-voltage connection between ignition transformer and ignition electrode

Choosing and fitting

Parts of this type are selected by length, connector pattern at both ends, and cable gauge. Before ordering, verify the cable's end fittings and overall length against the original. Inspect existing connector boots and terminal contacts for corrosion or looseness. The cable must match the original in connector type to ensure a secure, dry connection.

Signs of failure

A hardened or cracked insulation can allow the spark to track to earth, mimicking a faulty transformer. This may result in weak or no spark at the electrode gap. Check the insulation for damage and the terminal contacts for corrosion or looseness.

Fits equipment

Master 4110.971Master 4110.971 BV100Master 4110.971 BV160Master 4110.971 BV280Master 4110.971 BV110Master 4110.971 BV170Master 4110.971 BV290Master 4110.971 B230Master 4110.971 B360

All specifications

Silicone insulationsilicone-insulated
Insulation purposewithstand voltage and heat
Selection guidancelength, connector pattern, cable gauge
Failure imitationcan mimic faulty transformer
Heat resistancewithstand heat near combustion head

Part numbers

SKU09CA036109
Additional article309.616.001
ModelBV1