Cofi Ignition cable BV1 09CA036109
SKU 09CA036109
Model BV1
Brand Cofi
Photos
Key specifications
| Silicone insulation | silicone-insulated |
|---|---|
| Insulation purpose | withstand voltage and heat |
| Selection guidance | length, connector pattern, cable gauge |
| Failure imitation | can mimic faulty transformer |
| Heat resistance | withstand heat near combustion head |
24.86 EUR
22.60EUR
in stock · 5
incl. 21% VAT · 18.68 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Cofi Ignition cable BV1 09CA036109 is a replacement part for the high-voltage connection between the ignition transformer and the ignition electrode in a burner. It is silicone-insulated to withstand the voltage produced by the transformer and the heat near the combustion head. The cable transfers the secondary voltage that generates the spark at the electrode gap. It is compatible with Master 4110.971 models BV100, BV160, BV280, BV110, BV170, BV290, B230, and B360 up to 2010.
Further details
| Compatibility verification | verify end fittings and overall length against original |
|---|---|
| Compatible burners | Master 4110.971 BV100, BV160, BV280, BV110, BV170, BV290, B230, B360 until 2010 |
| Inspection requirement | inspect connector boots and terminal contacts for corrosion or looseness |
| Replacement part for | high-voltage connection between ignition transformer and ignition electrode |
Choosing and fitting
Parts of this type are selected by length, connector pattern at both ends, and cable gauge. Before ordering, verify the cable's end fittings and overall length against the original. Inspect existing connector boots and terminal contacts for corrosion or looseness. The cable must match the original in connector type to ensure a secure, dry connection.
Signs of failure
A hardened or cracked insulation can allow the spark to track to earth, mimicking a faulty transformer. This may result in weak or no spark at the electrode gap. Check the insulation for damage and the terminal contacts for corrosion or looseness.
Fits equipment
Master 4110.971Master 4110.971 BV100Master 4110.971 BV160Master 4110.971 BV280Master 4110.971 BV110Master 4110.971 BV170Master 4110.971 BV290Master 4110.971 B230Master 4110.971 B360
All specifications
| Silicone insulation | silicone-insulated |
|---|---|
| Insulation purpose | withstand voltage and heat |
| Selection guidance | length, connector pattern, cable gauge |
| Failure imitation | can mimic faulty transformer |
| Heat resistance | withstand heat near combustion head |
Part numbers
| SKU | 09CA036109 |
|---|---|
| Additional article | 309.616.001 |
| Model | BV1 |