Riello Ignition cable 3008490
SKU 3008490
Brand Riello
Photos
Key specifications
| Conductor cross-section | 0.75-1.5 |
|---|---|
| Insulation temperature class | F or H |
| Connector included | Yes |
| Soldering required | No |
| Flame detector type | Ionisation |
| Voltage type | Rectified voltage |
110.34 EUR
100.31EUR
in stock · 4
incl. 21% VAT · 82.90 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
This ionization cable for Riello gas boilers carries the low-voltage flame-signal current from the ionisation electrode to the burner control. The control applies a rectified voltage to the electrode during ignition, and the cable allows the small DC current from the flame to flow back. It has a conductor cross-section of 0.75–1.5 mm² and insulation temperature class F or H, suitable for proximity to the combustion head. Connectors are included, and no soldering is required for installation.
Further details
| Application | connecting temperature sensors or ionization electrodes |
|---|---|
| Common failure mode | Insulation brittleness or melting near the electrode |
| Connector matching | Matched by connector series, pin count, keying, conductor cross-section, insulation temperature class, overall length and terminal type |
| Function | Carries low-voltage flame-signal current from ionisation electrode to burner control |
| Terminal type options | Straight or angled plug, eyelet or spade on electrode end |
Choosing and fitting
Ionization cables of this type are selected by connector series, pin count and keying, conductor cross-section (typically 0.75–1.5 mm²), insulation temperature class (often F or H), overall length, and terminal type. When replacing, verify that the connector on the control board side fits securely and is keyed correctly; forced insertion can damage the pins. Check that the insulation is rated for the combustion head area, as temperatures there can be high.
Signs of failure
A broken, shorted, or high-resistance cable causes the control to fail to detect flame, resulting in lockout. Insulation brittleness or melting near the electrode is a common failure mode that produces intermittent flame loss. Poor contact at either connector can mimic almost any flame detection fault, so always check the cable as a standard step during lockout troubleshooting.
Fits equipment
Riello Gas boilersRiello gas boilersRiello Schneider Electric
All specifications
| Conductor cross-section | 0.75-1.5 |
|---|---|
| Insulation temperature class | F or H |
| Connector included | Yes |
| Soldering required | No |
| Flame detector type | Ionisation |
| Voltage type | Rectified voltage |
Part numbers
| SKU | 3008490 |
|---|---|
| Additional article | 916.298.001 |