Honeywell Piezo igniter Q635A1002B
SKU Q635A1002B
Brand Honeywell
Photos
Key specifications
| Construction type | piezo igniter (manual/single-channel) |
|---|---|
| Mounting location | front panel of boiler/heat generator |
| Actuator type | push-button and spark cable |
| Control features | manual ignition device |
| Catalogue article numbers | Q635A1002B, 534.634.900 |
| Power source | mechanical impact on piezoelectric element |
| Included accessories | mounting bracket |
| Wiring required | no |
35.94 EUR
32.67EUR
in stock · 2
incl. 21% VAT · 27.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
Manufactured by Honeywell, this ignition component (SKU Q635A1002B) is a manual/single-channel piezo igniter designed for front-panel mounting on a boiler or heat generator. It is operated by a push-button that mechanically impacts a piezoelectric element, generating a spark through a spark cable. The device requires no wiring and is supplied with a mounting bracket. It functions as a manual ignition device.
Further details
| Bracket mounting | bracket fixes igniter in correct position relative to pilot assembly |
|---|---|
| Design features | no maintenance, long service life, resistance to external influences |
| Ignition application | hand-operated ignition for boilers and burners |
| Installation Notes | check mounting thread size, electrode length, shaft configuration, bracket fit, spark gap setting |
| Maintenance and reliability | no maintenance required, designed for long service life and resistance to external influences |
Choosing and fitting
Piezo igniters of this kind are selected by matching the original part number and the geometry of the mounting bracket. Check the mounting thread size, electrode length, and shaft configuration against the original component before ordering. The bracket must align with the existing mounting holes on the boiler casing or door. Set the spark gap between the electrode and the pilot burner to the original specification; a gap that is too wide or too narrow can prevent ignition. Route the push-button and spark cable without sharp bends to avoid insulation damage.
Signs of failure
Typical failure modes include the absence of a characteristic blue spark when the push-button is pressed. A quieter or absent click inside the housing may indicate a failed piezoelectric element. Cracks or deformation of the housing, or damage to the insulation of the high-voltage wire, are also signs of malfunction. If the pilot burner fails to light, inspect these components for damage.
All specifications
| Construction type | piezo igniter (manual/single-channel) |
|---|---|
| Mounting location | front panel of boiler/heat generator |
| Actuator type | push-button and spark cable |
| Control features | manual ignition device |
| Catalogue article numbers | Q635A1002B, 534.634.900 |
| Power source | mechanical impact on piezoelectric element |
| Included accessories | mounting bracket |
| Wiring required | no |
Part numbers
| SKU | Q635A1002B |
|---|---|
| Additional article | 534.634.900 |