{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Anstoss Ignition transformer 07000079/04

SKU 07000079/04 Brand Anstoss

Photos

Key specifications

Supply voltage220–240 V
Temperature class-5/+185°F
Power consumption10 W
Frequency50–60 Hz
Ambient temperature, max85 °C
all specifications (5) ↓
41.69 EUR
37.90EUR
in stock · 5

incl. 21% VAT · 31.32 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Anstoss ignition transformer 07000079/04 is designed for ignition and stable operation of gas and oil burners in heating equipment. It generates a high-voltage pulse to ignite the fuel mixture, ensuring start-up of the ignition system. The device operates with a supply voltage of 220–240 V and a frequency of 50–60 Hz, consuming 10 W of power. It is rated for ambient temperatures up to 85 °C and has a temperature class of -5/+185°F. Its compact design facilitates convenient installation in ignition systems.

Further details

Advantagesstable spark generation; reliable burner start-up; compact housing; easy installation; resistance to voltage fluctuations; original anstoss product
Applicationdesigned for ignition and stable operation of gas and oil burners in heating equipment
Cable routinghigh-voltage output must be routed with adequate clearance from the burner case to avoid flashover
Energizationde-energised once the control confirms a stable flame
Functiongenerates a high-voltage pulse to ignite the fuel mixture and ensures reliable start-up of the ignition system
Grounding requirementthe transformer must be securely grounded
Ignition cable conditionignition cables are silicone-insulated to withstand high voltage and heat; a hardened or cracked cable will leak the spark to ground
Operating phaseoperates only during the ignition period, under command from the burner control
Replacement considerationsconfirm that the mounting footprint and cable connector pattern match the original, and that the duty cycle is sufficient for the burner's ignition sequence

Choosing and fitting

Parts of this type are selected primarily by secondary voltage and current, primary voltage (commonly 230 V, but 110 V and 24 V versions exist), duty cycle, mounting arrangement, terminal type, and connector pattern for the high-voltage cable. Before ordering, verify the primary voltage from the product label or technical data sheet, and confirm that the mounting footprint and cable connector pattern match the original. The transformer must be securely grounded, and the high-voltage output must be routed with adequate clearance from the burner case to avoid flashover.

Signs of failure

Items of this kind typically fail due to hardened or cracked ignition cables, which leak the spark to ground and can be mistaken for a failed transformer. Other failure modes include internal short circuits or open windings, leading to no spark at the ignition electrode. When such a failure occurs, the burner may fail to ignite or may shut down during operation. Check the secondary cable and electrode connections regularly, and inspect the transformer for signs of overheating or physical damage.

All specifications

Supply voltage220–240 V
Temperature class-5/+185°F
Power consumption10 W
Frequency50–60 Hz
Ambient temperature, max85 °C

Part numbers

SKU07000079/04
Additional article155.820.010