Anstoss Ignition transformer DCP 2/24 07000410
SKU 07000410
Model DCP 2/24
Brand Anstoss
Photos
Key specifications
| Ignition cable insulation | silicone |
|---|---|
| Secondary insulation | Insulated |
31.94 EUR
29.04EUR
in stock · 5
incl. 21% VAT · 24.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Anstoss DCP 2/24 07000410 is an ignition transformer used in burners and boilers. It steps up the mains voltage to a high level to produce a spark across the ignition electrode gap. The transformer is energized only during the ignition period, controlled by the burner control. It features silicone-insulated ignition cables and secondary insulation. The model is DCP 2/24, with SKU 07000410.
Choosing and fitting
When selecting an ignition transformer of this type, ensure the primary voltage (commonly 230 V, but also 110 V or 24 V) matches the burner's control circuit. Check the secondary voltage and current requirements, duty cycle, and physical mounting and terminal types. The cable connector pattern must match existing wiring. Verify the electrode gap and insulation condition before installation.
Signs of failure
Typical failures include cracked or hardened ignition cables that leak spark to earth, mimicking a faulty transformer. A weak spark may be due to cable condition rather than the transformer itself. Check the primary supply and electrode gap if ignition issues occur.
All specifications
| Ignition cable insulation | silicone |
|---|---|
| Secondary insulation | Insulated |
Part numbers
| SKU | 07000410 |
|---|---|
| Additional article | 155.820.036 |
| Model | DCP 2/24 |