Anstoss Ignition transformer DCQ 2/24 07000413/03
SKU 07000413/03
Model DCQ 2/24
Brand Anstoss
Photos
Key specifications
| Supply voltage | 24 V |
|---|---|
| Operating temperature | -20–85 °C |
| Permissible voltage deviation | ±15% |
| Output voltage frequency | PZU (24V) |
| Power consumption | 3.6 W |
27.95 EUR
25.41EUR
in stock · 5
incl. 21% VAT · 21.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Anstoss DCQ 2/24 ignition transformer is a component designed for burner equipment in heating systems. It generates a pulse for the ignition system, operating with a supply voltage of 24 V and a power consumption of 3. 6 W. The permissible voltage deviation is ±15%, and the output voltage frequency is PZU (24V). It operates within a temperature range of -20 to 85 °C. This transformer is used in gas and oil burners to ensure fuel ignition and stable operation of ignition automation.
Further details
| Advantages | reliable ignition; stable automation operation; compact size; easy installation; resistance to loads; original anstoss product |
|---|---|
| Application scope | designed for ignition and stable operation of burner equipment in heating and heat generation systems |
| Duty cycle | limited duty cycle; continuous energisation will cause overheating and failure |
| Energization | energised only during the ignition phase of the burner sequence, under command from the burner control |
| Function | generates a pulse for the ignition system and is used in gas and oil burners where reliable fuel ignition is required |
| Ignition cable condition | inspect the cable and connector for condition before installing the new transformer |
| Operating principle | steps up the mains supply voltage to the high level required to produce a spark at the ignition electrode gap |
| Replacement considerations | verify that the primary voltage and the high-voltage output match the burner control and electrode specifications |
Choosing and fitting
When selecting a replacement ignition transformer of this type, verify that the primary voltage and high-voltage output match the burner control and electrode specifications. Key parameters include the secondary voltage and current, primary voltage (common versions include 230 V, 110 V, and 24 V), duty cycle rating, mounting arrangement, and terminal configuration. The high-voltage cable connector pattern must match the existing electrode lead. Inspect the cable and connector for condition before installation.
Signs of failure
Ignition transformers of this kind can fail due to continuous energisation, which causes overheating and failure. A cracked or hardened ignition cable can leak the spark to earth, simulating a fault in the transformer even when the transformer is functional. Symptoms include failure to ignite the fuel, intermittent sparking, or no spark at the electrode. Check the transformer's primary voltage, high-voltage output, and the condition of the ignition cable and connector.
All specifications
| Supply voltage | 24 V |
|---|---|
| Operating temperature | -20–85 °C |
| Permissible voltage deviation | ±15% |
| Output voltage frequency | PZU (24V) |
| Power consumption | 3.6 W |
Part numbers
| SKU | 07000413/03 |
|---|---|
| Additional article | 155.820.011 |
| Model | DCQ 2/24 |