{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Anstoss Ignition transformer FZ 6 (TYPE1) 07000130/04

SKU 07000130/04 Model FZ 6 (TYPE1) Brand Anstoss

Photos

Key specifications

Supply voltage220–240 V
Length134 mm
Width33 mm
Height23 mm
Gross length140 mm
Manufacturer part number07000130/04
Ignition cable insulationhigh-voltage silicone-insulated cable
Net weight0.103 kg
Gross weight0.128 kg
Power consumption0.8 W
Frequency50–60 Hz
Ambient temperature, max120 °C
all specifications (12) ↓
25.20 EUR
22.91EUR
in stock · 5

incl. 21% VAT · 18.93 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Anstoss FZ 6 (TYPE1) ignition transformer, SKU 07000130/04, is designed for ignition and control systems in burner equipment. It converts a 220–240 V supply at 50–60 Hz to the high voltage needed for spark generation, with a power consumption of 0.8 W. The transformer operates in ambient temperatures up to 120 °C and measures 134 mm in length, 33 mm in width, and 23 mm in height, with a net weight of 0.103 kg. It features a high-voltage silicone-insulated ignition cable.

Further details

Advantagesstable voltage conversion; reliable operation in ignition systems; resistance to voltage fluctuations; compact design; original anstoss spare part
Application scopefor repair, maintenance, and replacement of ignition system components of boiler equipment
Energizationenergised only during the ignition phase, under command from the burner control
Functionsteps up mains voltage to the high level required to produce a spark across the gap of the ignition electrode
Troubleshootingcheck the ignition cable condition separately before condemning the transformer
Working withthe ignition electrode and the burner control

Choosing and fitting

When selecting a replacement ignition transformer of this type, verify that the primary voltage matches the system supply (e.g., 230 V, 110 V, or 24 V). Check the secondary voltage and current, duty cycle, mounting pattern, terminal style, and cable connector layout against the original part. Measure the physical dimensions and mounting hole positions to ensure compatibility. Always confirm the part number and manufacturer code before ordering.

Signs of failure

Common failures include internal short circuits or open windings, leading to no spark or weak spark at the ignition electrode. A damaged or hardened ignition cable can leak high voltage to earth, causing spark loss or erratic operation. Check the ignition cable condition separately before condemning the transformer, as a faulty cable can mimic transformer failure.

All specifications

Supply voltage220–240 V
Length134 mm
Width33 mm
Height23 mm
Gross length140 mm
Manufacturer part number07000130/04
Ignition cable insulationhigh-voltage silicone-insulated cable
Net weight0.103 kg
Gross weight0.128 kg
Power consumption0.8 W
Frequency50–60 Hz
Ambient temperature, max120 °C

Part numbers

SKU07000130/04
Additional article155.820.014
ModelFZ 6 (TYPE1)