Anstoss Ignition transformer FZ 6 (TYPE1) 07000130/04
SKU 07000130/04
Model FZ 6 (TYPE1)
Brand Anstoss
Photos
Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Length | 134 mm |
| Width | 33 mm |
| Height | 23 mm |
| Gross length | 140 mm |
| Manufacturer part number | 07000130/04 |
| Ignition cable insulation | high-voltage silicone-insulated cable |
| Net weight | 0.103 kg |
| Gross weight | 0.128 kg |
| Power consumption | 0.8 W |
| Frequency | 50–60 Hz |
| Ambient temperature, max | 120 °C |
25.20 EUR
22.91EUR
in stock · 5
incl. 21% VAT · 18.93 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Anstoss FZ 6 (TYPE1) ignition transformer, SKU 07000130/04, is designed for ignition and control systems in burner equipment. It converts a 220–240 V supply at 50–60 Hz to the high voltage needed for spark generation, with a power consumption of 0.8 W. The transformer operates in ambient temperatures up to 120 °C and measures 134 mm in length, 33 mm in width, and 23 mm in height, with a net weight of 0.103 kg. It features a high-voltage silicone-insulated ignition cable.
Further details
| Advantages | stable voltage conversion; reliable operation in ignition systems; resistance to voltage fluctuations; compact design; original anstoss spare part |
|---|---|
| Application scope | for repair, maintenance, and replacement of ignition system components of boiler equipment |
| Energization | energised only during the ignition phase, under command from the burner control |
| Function | steps up mains voltage to the high level required to produce a spark across the gap of the ignition electrode |
| Troubleshooting | check the ignition cable condition separately before condemning the transformer |
| Working with | the ignition electrode and the burner control |
Choosing and fitting
When selecting a replacement ignition transformer of this type, verify that the primary voltage matches the system supply (e.g., 230 V, 110 V, or 24 V). Check the secondary voltage and current, duty cycle, mounting pattern, terminal style, and cable connector layout against the original part. Measure the physical dimensions and mounting hole positions to ensure compatibility. Always confirm the part number and manufacturer code before ordering.
Signs of failure
Common failures include internal short circuits or open windings, leading to no spark or weak spark at the ignition electrode. A damaged or hardened ignition cable can leak high voltage to earth, causing spark loss or erratic operation. Check the ignition cable condition separately before condemning the transformer, as a faulty cable can mimic transformer failure.
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Length | 134 mm |
| Width | 33 mm |
| Height | 23 mm |
| Gross length | 140 mm |
| Manufacturer part number | 07000130/04 |
| Ignition cable insulation | high-voltage silicone-insulated cable |
| Net weight | 0.103 kg |
| Gross weight | 0.128 kg |
| Power consumption | 0.8 W |
| Frequency | 50–60 Hz |
| Ambient temperature, max | 120 °C |
Part numbers
| SKU | 07000130/04 |
|---|---|
| Additional article | 155.820.014 |
| Model | FZ 6 (TYPE1) |