Anstoss Ignition transformer UBZ 4 (12) TYPE1 07000581
SKU 07000581
Model UBZ 4 (12) TYPE1
Brand Anstoss
Photos
Key specifications
| Supply voltage | 12 V |
|---|---|
| Length | 88 mm |
| Width | 33 mm |
| Height | 30 mm |
| Voltage tolerance | +20% / -30% |
| Design variant | 4000 |
| Application range | +14…+248°F |
| Power consumption | 1.5 W |
| Ambient temperature, max | 120 °C |
31.94 EUR
29.04EUR
in stock · 1
incl. 21% VAT · 24.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Anstoss UBZ 4 (12) TYPE1 ignition transformer (SKU 07000581) is designed for ignition systems in gas and liquid fuel burners. It operates at a supply voltage of 12 V with a power consumption of 1.5 W. The transformer has dimensions of 88 mm x 33 mm x 30 mm and can withstand ambient temperatures up to 120 °C. Its voltage tolerance is +20% / -30%, and it is suitable for applications within a temperature range of +14 to +248 °F. This component is used as a replacement part in boiler and burner equipment.
Further details
| Advantages | stable ignition of burner equipment; resistance to voltage fluctuations; compact size; reliable operation at high temperatures; original anstoss spare part |
|---|---|
| Energization | energised only during the ignition phase of the burner sequence, under command from the burner control |
| Function | step up the mains supply voltage to a level sufficient to produce a spark across the gap of the ignition electrode |
| Troubleshooting | inspect the cable and the electrode assembly when diagnosing an ignition fault |
Choosing and fitting
When selecting an ignition transformer of this type, ensure the primary voltage, secondary voltage and current, duty cycle, mounting style, terminal type, and ignition cable connector pattern match the original. Measure the physical dimensions and compare the voltage tolerance and ambient temperature limits to the application requirements. Inspect the high-voltage cable and electrode assembly for damage before installation, as a faulty cable can mimic transformer failure.
Signs of failure
Common failure modes for ignition transformers include internal short circuits, open windings, or insulation breakdown, leading to weak or no spark at the ignition electrode. Equipment may fail to ignite, cycle on safety lockout, or produce intermittent ignition. Check the transformer's input voltage and output spark, and inspect the high-voltage cable for cracks or hardening that could cause spark leakage to ground.
All specifications
| Supply voltage | 12 V |
|---|---|
| Length | 88 mm |
| Width | 33 mm |
| Height | 30 mm |
| Voltage tolerance | +20% / -30% |
| Design variant | 4000 |
| Application range | +14…+248°F |
| Power consumption | 1.5 W |
| Ambient temperature, max | 120 °C |
Part numbers
| SKU | 07000581 |
|---|---|
| Additional article | 155.820.030 |
| Model | UBZ 4 (12) TYPE1 |