{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Anstoss Ignition transformer ZAG 2 07000088/03

SKU 07000088/03 Model ZAG 2 Brand Anstoss

Photos

Key specifications

Supply voltage220–240 V
Version10 Hz
Design featurescompact design allows easy installation
Ignition cable insulationsilicone-insulated cables
Power consumption2.5 W
Frequency50–60 Hz
Ambient temperature, max85 °C
all specifications (7) ↓
14.45 EUR
13.14EUR
in stock · 5

incl. 21% VAT · 10.86 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Anstoss ZAG 2 ignition transformer (SKU 07000088/03) is a Type 1 device designed for burner equipment in heating systems. It operates on a supply voltage of 220–240 V at 50–60 Hz, with a power consumption of 2.5 W. The transformer generates a high-voltage pulse to ignite the fuel mixture in gas and oil burners, ensuring stable spark generation. Its compact design facilitates easy installation in automatic ignition systems. The maximum ambient temperature is 85 °C, and it features silicone-insulated ignition cables.

Further details

Advantagesstable ignition system operation; reliable spark generation; compact size; easy installation; resistance to voltage fluctuations; original anstoss product
Functionsteps mains voltage up to the level required to generate a spark across the ignition electrode gap
Operating phaseoperates only during the ignition period, under command from the burner control
Troubleshootinginspect ignition cable thoroughly; check electrode gap and condition of ceramic insulator; verify control sends mains supply during ignition phase and ground connection is clean and tight

Choosing and fitting

When selecting a replacement ignition transformer of this kind, verify that the primary voltage, frequency, and power rating match the burner's control circuit. The mounting arrangement and terminal type must be compatible with the existing installation, and the high-voltage cable connector pattern should align. Measure the physical dimensions and compare the duty cycle to ensure suitability. Inspect the ignition cable for hardening or cracks, as damaged silicone insulation can cause spark leakage.

Signs of failure

Typical failures of ignition transformers include internal short circuits or open windings, leading to no spark or weak spark at the electrode. The burner may fail to ignite or lock out after repeated ignition attempts. Check the transformer's primary voltage during the ignition phase, inspect the high-voltage cable for insulation breakdown, and verify the electrode gap and ground connection to the chassis.

All specifications

Supply voltage220–240 V
Version10 Hz
Design featurescompact design allows easy installation
Ignition cable insulationsilicone-insulated cables
Power consumption2.5 W
Frequency50–60 Hz
Ambient temperature, max85 °C

Part numbers

SKU07000088/03
Additional article155.820.007
ModelZAG 2
Type designationTYPE1