{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Brahma Ignition transformer 15909025

SKU 15909025 Brand Brahma

Photos

Key specifications

Maximum length of ignition cable with integrated electronic ignition1 m
Recommended spark distance2–4 mm
Protection class (IP)IP00
Duration of ED(DU) operation100 %
Number of outputs1
Installation positionany position
Grounding requirementensure reliable grounding
Grounding pointarrange grounding at one point
Interference reductionreduce electromagnetic interference
Compatible articlesst15165, 41651
Duty cycle100%
Net weight0.055 kg
Power consumption2.5 W
all specifications (13) ↓
55.90 EUR
50.82EUR
in stock · 1

incl. 21% VAT · 42.00 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

Brahma Ignition transformer 15909025 is a single-output ignition transformer with a duty cycle of 100%, designed for use in atmospheric gas burners. It has a power consumption of 2.5 W, a recommended spark distance of 2–4 mm, and supports an ignition cable up to 1 m in length. The transformer weighs 0.055 kg, has protection class IP00, and can be installed in any position. It is compatible with BRAHMA TR2, Mora 5106.1032, and Thermona 5106.1032, and corresponds to type designations 01289096, ST15165, and 41651.

Further details

Application scopeatmospheric gas burners in wall-mounted boilers, water heaters, air heaters, convectors, floor boilers
Compatible boilersMora and Thermona boilers 5106.1032, 5107.1032, 5109.1032, 5111.1032
Compatible controllersfc modules, cm controllers fr and dmr dtmr
Optional resistorsresistors can be installed to reduce interference
PatentItalian patent no. 01289096 issued on 09/25/1998: ignition device for flare burners with a reduced level of radio interference

Choosing and fitting

When selecting an ignition transformer of this type, ensure the output voltage, duty cycle, and number of outputs match the burner's requirements. The transformer must be compatible with the specific boiler model and its electrical circuit, including flame control and safety devices. Installation should be performed with power off, following national and European safety standards. The transformer can be mounted in any position, but high-voltage cables should be kept short and routed away from other cables to minimize interference. Grounding must be and arranged at a single point to prevent parasitic currents.

Signs of failure

Typical failures of ignition transformers include internal short circuits or open windings, leading to no spark or weak spark at the electrode. This may cause the burner to fail to ignite or to ignite intermittently. Check the transformer's output voltage with a suitable meter, inspect the ignition cable for damage or excessive length, and verify the spark gap is within the recommended range. Also, ensure proper grounding and that the transformer is not overheating due to continuous operation beyond its duty cycle.

Fits equipment

BRAHMA TR2Mora 5106.1032Thermona 5106.1032

All specifications

Maximum length of ignition cable with integrated electronic ignition1 m
Recommended spark distance2–4 mm
Protection class (IP)IP00
Duration of ED(DU) operation100 %
Number of outputs1
Installation positionany position
Grounding requirementensure reliable grounding
Grounding pointarrange grounding at one point
Interference reductionreduce electromagnetic interference
Compatible articlesst15165, 41651
Duty cycle100%
Net weight0.055 kg
Power consumption2.5 W

Part numbers

SKU15909025
Additional article246.820.028
Type designation01289096
Type designationST15165
Type designation41651