{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Brahma Ignition transformer 15909105

SKU 15909105 Brand Brahma

Photos

Key specifications

Secondary voltage15 kV
Poles / outlets1
Operating temperature-20–60 °C
Recommended spark distance2–4 mm
Maximum length of ignition cable with integrated electronic ignition1 m
Output voltage frequency15 kHz
Duration of ED(DU) operation100 %
Number of outputs1
Ingress protectionIP00
Installation positionany
Grounding requirementensure reliable grounding
Grounding pointsingle point
Duty cycle100%
Net weight0.055 kg
Power consumption2.5 W
all specifications (15) ↓
55.90 EUR
50.82EUR
in stock · 2

incl. 21% VAT · 42.00 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Brahma Ignition Transformer 15909105 is a single-output ignition transformer designed for gas devices, reducing electromagnetic interference. It operates at a secondary voltage of 15 kV with a frequency of 15 kHz and consumes 2.5 W of power. The transformer has a duty cycle of 100%, allowing continuous operation, and is rated for an operating temperature range of -20 to 60 °C. It features an ingress protection rating of IP00 and weighs 0.055 kg. The recommended spark distance is 2–4 mm, and the maximum ignition cable length is 1 m.

Further details

Cable routingdo not place high-voltage cables next to other cables; route ignition cables close to ground busbar
Electromagnetic interference reductiondesigned for gas devices, reducing electromagnetic interference
ProtectionIP00

Choosing and fitting

When selecting an ignition transformer of this type, ensure that the output voltage, frequency, and power consumption match the burner's requirements. The transformer must be installed in any position, but grounding at a single point is essential to prevent parasitic currents. The ignition cable should be kept as short as possible and routed close to the ground busbar to minimize interference. Installation should be performed only with the power off, following national and European safety standards.

Signs of failure

Ignition transformers of this kind may fail due to insulation breakdown, leading to weak or no spark. Symptoms include intermittent ignition, burner lockout, or failure to start. Check for visible damage, carbon tracking, or short circuits in the high-voltage cable and connections. Ensure the spark gap is within the recommended range and that the transformer is properly grounded.

Fits equipment

Brahma TR2/A Weight 55 g.

All specifications

Secondary voltage15 kV
Poles / outlets1
Operating temperature-20–60 °C
Recommended spark distance2–4 mm
Maximum length of ignition cable with integrated electronic ignition1 m
Output voltage frequency15 kHz
Duration of ED(DU) operation100 %
Number of outputs1
Ingress protectionIP00
Installation positionany
Grounding requirementensure reliable grounding
Grounding pointsingle point
Duty cycle100%
Net weight0.055 kg
Power consumption2.5 W

Part numbers

SKU15909105
Additional article246.820.110