Brahma Ignition transformer 15930100
SKU 15930100
Brand Brahma
Photos
Key specifications
| Supply voltage | 230 V |
|---|---|
| Secondary voltage | 4–13 kV |
| Poles / outlets | 2 |
| Protection | IP 00 |
| Recommended spark distance | 3–5 mm |
| Maximum length of ignition cable with integrated electronic ignition | 1.5 m |
| Output voltage frequency | 10 kHz |
| Peak current (mA) | 62 mA |
| Rated current (mA) | 30 mA |
| Number of contacts | 2 |
| Peak voltage | 17 kV |
| Current frequency | 50–60 Hz |
| Duration of ED(DU) operation | 33 % |
| Built-in filter | yes |
| Dimensional series compatibility | TC and TD series |
| High efficiency | yes |
| Single or double-pin high voltage output | single or double-pin |
| Mounting and connecting systems | various |
| Short-circuit protection | built-in |
| Low voltage directive | 2006/95/ec |
| IMQ resolution | EN 61558-1:2005+A1:2009 and EN 61558-2-3:2010 |
| Varistor protection | built-in varistor |
| Installation position | any |
| Ferritic core | yes |
| High-frequency generator | yes |
| Compact design | extremely compact overall dimensions |
| Complies with directive | 2004/108/ec |
| External filter not required | yes |
| Protection against temperature fluctuations | special composition |
| Safety standard | EN 61558-1:2005+A1:2009 and EN 61558-2-3:2010 |
| Weight | about 250 g |
| Secondary current | 30 mA |
| Duty cycle | 33% |
| Net weight | 0.25 kg |
| Power consumption | yes |
| Frequency | 50 Hz |
119.79 EUR
108.90EUR
in stock · 2
incl. 21% VAT · 90.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma Ignition transformer 15930100 is a compact, high-frequency electronic ignition transformer designed for use in gas and liquid fuel burners. It operates with a supply voltage of 230 V and a frequency of 50 Hz, delivering a secondary voltage of 4–13 kV at a frequency of 10 kHz. The transformer features a built-in filter, varistor protection, and short-circuit protection, and it complies with directives 2006/95/ec and 2004/108/ec. It has a duty cycle of 33%, a recommended spark distance of 3–5 mm, and a maximum ignition cable length of 1.5 m. The unit weighs approximately 0.25 kg and is compatible with TC and TD series dimensions.
Further details
| Application scope | gas burners, burners for light and heavy liquid fuels in domestic, commercial, industrial installations |
|---|---|
| Connector availability | all connectors, including cable connectors, are available on request |
| Connector options | triangular connector SP1 or connector 6.35x0.8 |
| Custom cable options | cable length and end can be changed on request |
| Grounding requirement | valve body must be connected to ground |
| Operating principle | high-frequency electronic generator increases voltage via transformer with ferritic core |
| Overload protection | special composition with high thermal conductivity and special expansion coefficient |
| Replacement capability | replace most transformers from other manufacturers |
| Thermal compound | special composition with high thermal conductivity and special expansion coefficient |
Choosing and fitting
When selecting an ignition transformer of this type, ensure the supply voltage and frequency match the burner's electrical system. Verify the secondary voltage and current ratings are suitable for the ignition application. The transformer must have the correct mounting configuration and high-voltage output connector type (single or double-pin) to fit the existing wiring. Check the physical dimensions to ensure compatibility with the burner's mounting space, and confirm the protection rating meets the installation environment requirements.
Signs of failure
Common failures in ignition transformers include internal short circuits, open windings, or breakdown of insulation, leading to weak or no spark. Symptoms may include the burner failing to ignite, intermittent ignition, or a buzzing sound from the transformer. Check for visible damage, measure the secondary voltage with a suitable probe, and verify the primary supply voltage and continuity of the ignition cable.
All specifications
| Supply voltage | 230 V |
|---|---|
| Secondary voltage | 4–13 kV |
| Poles / outlets | 2 |
| Protection | IP 00 |
| Recommended spark distance | 3–5 mm |
| Maximum length of ignition cable with integrated electronic ignition | 1.5 m |
| Output voltage frequency | 10 kHz |
| Peak current (mA) | 62 mA |
| Rated current (mA) | 30 mA |
| Number of contacts | 2 |
| Peak voltage | 17 kV |
| Current frequency | 50–60 Hz |
| Duration of ED(DU) operation | 33 % |
| Built-in filter | yes |
| Dimensional series compatibility | TC and TD series |
| High efficiency | yes |
| Single or double-pin high voltage output | single or double-pin |
| Mounting and connecting systems | various |
| Short-circuit protection | built-in |
| Low voltage directive | 2006/95/ec |
| IMQ resolution | EN 61558-1:2005+A1:2009 and EN 61558-2-3:2010 |
| Varistor protection | built-in varistor |
| Installation position | any |
| Ferritic core | yes |
| High-frequency generator | yes |
| Compact design | extremely compact overall dimensions |
| Complies with directive | 2004/108/ec |
| External filter not required | yes |
| Protection against temperature fluctuations | special composition |
| Safety standard | EN 61558-1:2005+A1:2009 and EN 61558-2-3:2010 |
| Weight | about 250 g |
| Secondary current | 30 mA |
| Duty cycle | 33% |
| Net weight | 0.25 kg |
| Power consumption | yes |
| Frequency | 50 Hz |
Part numbers
| SKU | 15930100 |
|---|---|
| Additional article | 246.820.064 |