Brahma Ignition transformer T11/B 15066001
SKU 15066001
Model T11/B
Brand Brahma
Photos
Key specifications
| Supply voltage | 220 V |
|---|---|
| Secondary voltage | 9 kV |
| Poles / outlets | 1 |
| Length | 110 mm |
| Width | 96 mm |
| Height | 78 mm |
| Ingress protection | ip 00 |
| Recommended spark distance | 3–5 mm |
| Standard power cable length | 550 mm |
| Winding insulation | polyester resin |
| Insulator material | 30% pbt glass fiber |
| Secondary grounding | grounded in the center |
| Peak voltage | 15 kV |
| Mounting feature | any position |
| Weight | 2 g |
| Shape | shell |
| Electromagnetic interference protection | radio interference suppression screen |
| RF shield grounding | requires reliable grounding |
| Mounting and connecting systems | standard (T11) |
| Secondary current | 20 mA |
| Duty cycle | 33% in 3 minutes |
| Power consumption | 240 W |
| Frequency | 50 Hz |
251.56 EUR
228.69EUR
in stock · 3
incl. 21% VAT · 189.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
Brahma 15066001 (model T11/B) is an ignition transformer intended for burners that run on liquid or gaseous fuel. It operates from a 220 V, 50 Hz supply and produces a secondary voltage of 9 kV at 20 mA, with a peak of 15 kV. The duty cycle is 33% in 3 minutes and the power consumption is 240 W. It has one pole, protection class IP00, recommended spark gap of 3–5 mm, and comes with a standard power cable of 550 mm.
Further details
| Connector options | screw terminal or cylindrical terminal (4 mm or 6.3 mm) |
|---|---|
| Fire retardant caps | two caps painted with flame retardant paint |
| Grounding requirement | transformer ground and electrical system ground must be well connected |
Choosing and fitting
Transformers of this type are selected by matching the supply voltage and required ignition voltage to the burner. The mounting system (e.g., standard T11) and high-voltage terminal shape (screw or cylindrical 4 mm/6.3 mm) must also match the burner's bracket and cable. Before installation or removal, switch off the power supply. Connect the transformer ground and system ground at a single point. The unit can be mounted in any position; route the ignition cable as short as possible and away from other cables.
All specifications
| Supply voltage | 220 V |
|---|---|
| Secondary voltage | 9 kV |
| Poles / outlets | 1 |
| Length | 110 mm |
| Width | 96 mm |
| Height | 78 mm |
| Ingress protection | ip 00 |
| Recommended spark distance | 3–5 mm |
| Standard power cable length | 550 mm |
| Winding insulation | polyester resin |
| Insulator material | 30% pbt glass fiber |
| Secondary grounding | grounded in the center |
| Peak voltage | 15 kV |
| Mounting feature | any position |
| Weight | 2 g |
| Shape | shell |
| Electromagnetic interference protection | radio interference suppression screen |
| RF shield grounding | requires reliable grounding |
| Mounting and connecting systems | standard (T11) |
| Secondary current | 20 mA |
| Duty cycle | 33% in 3 minutes |
| Power consumption | 240 W |
| Frequency | 50 Hz |
Part numbers
| SKU | 15066001 |
|---|---|
| Additional article | 246.820.084 |
| Model | T11/B |