{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Brahma Ignition transformer T11/M 15093001

SKU 15093001 Model T11/M Brand Brahma

Photos

Key specifications

Supply voltage220 V
Secondary voltage9 kV
Poles / outlets1
Length110 mm
Width96 mm
Height78 mm
Body materialPBT with 30% fiberglass
Installation typeany position
Weight2000 g
Electrical insulationpolyester resin
Secondary current20 mA
Duty cycle33% in 3 minutes
Net weight2 kg
Power consumption240 W
Frequency50 Hz
all specifications (15) ↓
216.43 EUR
196.75EUR
in stock · 6

incl. 21% VAT · 162.60 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Brahma ignition transformer T11/M 15093001 is designed for use in burners operating on liquid or gaseous fuels. It operates with a supply voltage of 220 V at 50 Hz, providing a secondary voltage of 9 kV and a secondary current of 20 mA. The transformer has a duty cycle of 33% in 3 minutes and consumes 240 W of power. Its body is made of PBT with 30% fiberglass, and it weighs 2 kg. The unit measures 110 mm in length, 96 mm in width, and 78 mm in height, with insulation made of polyester resin.

Further details

Construction Typemagnetic circuit in the form of a shell

Choosing and fitting

When selecting an ignition transformer of this type, ensure that the supply voltage, frequency, secondary voltage, and current ratings match the burner's requirements. The mounting system may vary; models with standard mounting are designated without a suffix letter, while others may include a letter indicating a different mounting arrangement. Check the physical dimensions and connection type (e.g., screw terminal) to ensure compatibility with the existing setup. The transformer can be installed in any position, but proper grounding is essential for safe operation.

Signs of failure

Common failure modes for ignition transformers include insulation breakdown, which can cause short circuits or loss of spark. Symptoms may include the burner failing to ignite or intermittent ignition. Check for visible damage to the casing or connections, and verify the output voltage with a suitable meter. Ensure the ground connection is secure, as poor grounding can lead to erratic behavior.

All specifications

Supply voltage220 V
Secondary voltage9 kV
Poles / outlets1
Length110 mm
Width96 mm
Height78 mm
Body materialPBT with 30% fiberglass
Installation typeany position
Weight2000 g
Electrical insulationpolyester resin
Secondary current20 mA
Duty cycle33% in 3 minutes
Net weight2 kg
Power consumption240 W
Frequency50 Hz

Part numbers

SKU15093001
Additional article246.820.003
ModelT11/M