Brahma Ignition transformer T11/MC 15096001
SKU 15096001
Model T11/MC
Brand Brahma
Photos
Key specifications
| Supply voltage | 220 V |
|---|---|
| Poles / outlets | 1 |
| Length | 101 mm |
| Width | 80 mm |
| Height | 82 mm |
| Electrical insulation | polyester resin |
| Recommended spark distance | 3–5 mm |
| Standard power cable length | 550 mm |
| Input effective current | 1.1 |
| Protection class (IP) | IP00 |
| Insulator material | 30% PBT glass fiber |
| Secondary current | 20 mA |
| Duty cycle | 33% in 3 minutes |
| Net weight | 3.5 kg |
| Power consumption | 240 W |
| Frequency | 50 Hz |
395.31 EUR
359.37EUR
in stock · 2
incl. 21% VAT · 297.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma Ignition transformer T11/MC 15096001 is designed for use in burners operating on liquid or gaseous fuels. It operates at a supply voltage of 220 V and a frequency of 50 Hz, with a power consumption of 240 W. The transformer provides a secondary current of 20 mA and has a duty cycle of 33% in 3 minutes. It features one pole, measures 101 mm in length, 80 mm in width, and 82 mm in height, with a net weight of 3.5 kg. The insulation is made of polyester resin, and the insulator material is 30% PBT glass fiber. The recommended spark distance is 3–5 mm, and the standard power cable length is 550 mm. The protection class is IP00.
Choosing and fitting
When selecting a replacement ignition transformer of this type, ensure that the supply voltage, frequency, and power consumption match the burner's electrical specifications. The physical dimensions and mounting method must be compatible with the existing installation. The high-voltage cable connection type (screw terminal or cylindrical terminal with a diameter of 4 mm or 6.3 mm) should be verified to match the existing wiring. The recommended spark distance and duty cycle must be suitable for the burner's operational requirements.
Signs of failure
Common failure modes for ignition transformers of this kind include internal short circuits or open windings, leading to a lack of spark or weak spark at the electrodes. This may result in the burner failing to ignite or experiencing intermittent flame loss. Check for visible damage, overheating, or signs of electrical arcing on the transformer casing. Measure the input and output voltages with a multimeter to confirm proper operation.
All specifications
| Supply voltage | 220 V |
|---|---|
| Poles / outlets | 1 |
| Length | 101 mm |
| Width | 80 mm |
| Height | 82 mm |
| Electrical insulation | polyester resin |
| Recommended spark distance | 3–5 mm |
| Standard power cable length | 550 mm |
| Input effective current | 1.1 |
| Protection class (IP) | IP00 |
| Insulator material | 30% PBT glass fiber |
| Secondary current | 20 mA |
| Duty cycle | 33% in 3 minutes |
| Net weight | 3.5 kg |
| Power consumption | 240 W |
| Frequency | 50 Hz |
Part numbers
| SKU | 15096001 |
|---|---|
| Additional article | 246.820.043 |
| Model | T11/MC |