Brahma Ignition transformer T13/M 15177061
SKU 15177061
Model T13/M
Brand Brahma
Photos
Key specifications
| Supply voltage | 220 V |
|---|---|
| Secondary voltage | 8 kV |
| Poles / outlets | 1 |
| Length | 110 mm |
| Width | 96 mm |
| Height | 78 mm |
| Body material | PBT with 30% fiberglass |
| Installation type | any position |
| Recommended spark distance | 3–5 mm |
| Mounting systems variety | different mounting systems |
| Default connection insulator | screw terminal |
| Grounding point | single grounding center |
| Protection class (IP) | IP00 |
| Input effective current | 0.65 |
| Dimensions | 11x9.6x7.8 cm |
| Weight | 2000 g |
| Mounting feature | any position |
| Standard power cable length | 550 mm |
| Electrical insulation | polyester resin |
| Secondary grounding | grounded in the center |
| RF shield grounding | must be securely grounded |
| Secondary current | 16 mA |
| Duty cycle | 100% |
| Net weight | 2 kg |
| Power consumption | 145 W |
| Frequency | 50 Hz |
180.49 EUR
164.08EUR
in stock · 2
incl. 21% VAT · 135.60 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma T13/M ignition transformer (SKU 15177061) is designed for burners operating on liquid or gaseous fuels. It operates with a supply voltage of 220 V at 50 Hz, delivering a secondary voltage of 8 kV and a secondary current of 16 mA. The transformer has a duty cycle of 100%, power consumption of 145 W, and an input effective current of 0.65 A. It features a PBT body with 30% fiberglass, polyester resin insulation, and a single grounding center. The unit measures 110x96x78 mm, weighs 2 kg, and has a protection class of IP00.
Further details
| Construction Type | magnetic circuit in the form of a shell |
|---|---|
| Designation | letter T followed by model numbers |
| Fire Retardant Caps | two caps painted with flame retardant paint |
| High Voltage Cables Placement | avoid placing high voltage cables next to other cables |
Choosing and fitting
When selecting a replacement ignition transformer of this type, verify that the supply voltage, frequency, secondary voltage, and secondary current match the burner's requirements. Check the mounting system and dimensions to ensure compatibility with the existing bracket. The connection insulator is typically a screw terminal unless otherwise specified; confirm the high-voltage cable connector type. The transformer can be installed in any position, but the grounding point must be securely connected to the system ground.
Signs of failure
Common failure modes for ignition transformers include shorted or open secondary windings, insulation breakdown, and grounding issues. Symptoms may include weak or no spark at the electrodes, intermittent ignition, or burner lockout. Check the secondary voltage with a suitable probe, inspect for visible damage or burning, and verify that the grounding shield is properly connected.
All specifications
| Supply voltage | 220 V |
|---|---|
| Secondary voltage | 8 kV |
| Poles / outlets | 1 |
| Length | 110 mm |
| Width | 96 mm |
| Height | 78 mm |
| Body material | PBT with 30% fiberglass |
| Installation type | any position |
| Recommended spark distance | 3–5 mm |
| Mounting systems variety | different mounting systems |
| Default connection insulator | screw terminal |
| Grounding point | single grounding center |
| Protection class (IP) | IP00 |
| Input effective current | 0.65 |
| Dimensions | 11x9.6x7.8 cm |
| Weight | 2000 g |
| Mounting feature | any position |
| Standard power cable length | 550 mm |
| Electrical insulation | polyester resin |
| Secondary grounding | grounded in the center |
| RF shield grounding | must be securely grounded |
| Secondary current | 16 mA |
| Duty cycle | 100% |
| Net weight | 2 kg |
| Power consumption | 145 W |
| Frequency | 50 Hz |
Part numbers
| SKU | 15177061 |
|---|---|
| Additional article | 246.820.060 |
| Model | T13/M |