Brahma Ignition transformer T14/T 15288002

SKU 15288002 Model T14/T Brand Brahma

Photos

Key specifications

Supply voltage220 V
Secondary voltage4.5 kV
Poles / outlets2
Length150 mm
Width101 mm
Height80 mm
Body materialpressed metal coated with enamel
Construction typecolumn-type transformers
Electrical connectionscrew connection or cylindrical terminal
Dimensions15x10.1x8 cm
Weight3500 g
Nominal current25 mA
Ingress protectionIP00
Rated current (mA)25 mA
Standard power cable length550 mm
Mounting featureany position
Electrical insulationpolyester resin
Ignition current25 mA
Dust and moisture protectionIP00
Number of outputs2
Duration of ED(DU) operation25 %
High voltage outputs2
Housing materialpressed metal coated with enamel
Power supply220V
Power cable length included550 mm
Current1.3 A
ProtectionIP00
Number of poles2
Protection class (IP)IP00
connection_typescrew connection or cylindrical terminal
Current consumption1.3 A
Installation positionany position
Secondary current25 mA
Duty cycle25 %
Net weight3.5 kg
Frequency50 Hz
all specifications (36) ↓
206.04 EUR
187.31EUR
in stock · 3

incl. 21% VAT · 154.80 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Brahma T14/T ignition transformer (SKU 15288002) is a column-type transformer designed for use in burners with high thermal output or pressure burners operating on light or heavy oil. It operates on a 220 V supply at 50 Hz, drawing 1.3 A, and provides a secondary voltage of 4.5 kV with a secondary current of 25 mA. The transformer has a duty cycle of 25%, two high-voltage outputs, and is housed in a pressed metal case coated with enamel. It weighs 3.5 kg and measures 15x10.1x8 cm, with a power cable length of 550 mm included. The unit is rated IP00 and can be mounted in any position.

Further details

Winding Configurationtwo primary windings and two secondary windings
Winding Insulationspecial separator with high degree of insulation

Choosing and fitting

When selecting an ignition transformer of this type, ensure the supply voltage, frequency, secondary voltage, and current ratings match the burner's requirements. The mounting system and electrical connection type (screw or cylindrical terminal) must be compatible with the existing setup. Verify the physical dimensions and weight to ensure proper fit, and confirm the duty cycle aligns with the application's operational demands. Installation should be performed with the power disconnected, and the transformer can be mounted in any position.

Signs of failure

Common failure modes for ignition transformers include internal winding shorts or open circuits, often caused by moisture ingress or overheating. Symptoms may include weak or no spark at the electrodes, intermittent ignition, or tripping of the burner's safety controls. Check for visible damage to the housing, loose connections, and measure the secondary voltage with a suitable high-voltage probe to confirm output. Also inspect the ignition cables for cracks or insulation breakdown, which can cause arcing and reduce spark intensity.

All specifications

Supply voltage220 V
Secondary voltage4.5 kV
Poles / outlets2
Length150 mm
Width101 mm
Height80 mm
Body materialpressed metal coated with enamel
Construction typecolumn-type transformers
Electrical connectionscrew connection or cylindrical terminal
Dimensions15x10.1x8 cm
Weight3500 g
Nominal current25 mA
Ingress protectionIP00
Rated current (mA)25 mA
Standard power cable length550 mm
Mounting featureany position
Electrical insulationpolyester resin
Ignition current25 mA
Dust and moisture protectionIP00
Number of outputs2
Duration of ED(DU) operation25 %
High voltage outputs2
Housing materialpressed metal coated with enamel
Power supply220V
Power cable length included550 mm
Current1.3 A
ProtectionIP00
Number of poles2
Protection class (IP)IP00
connection_typescrew connection or cylindrical terminal
Current consumption1.3 A
Installation positionany position
Secondary current25 mA
Duty cycle25 %
Net weight3.5 kg
Frequency50 Hz

Part numbers

SKU15288002
Additional article246.820.114
ModelT14/T