Brahma Ignition transformer T16/MC 15360001
SKU 15360001
Model T16/MC
Brand Brahma
Photos
Key specifications
| Supply voltage | 220 V |
|---|---|
| Secondary voltage | 8 kV |
| Poles / outlets | 2 |
| Length | 115 mm |
| Width | 80 mm |
| Height | 78 mm |
| Body material | PBT with 30% fiberglass |
| Installation type | any position |
| Electrical connection | screw terminal |
| Dimensions | 11.5x8x7.8 cm |
| Weight | 2000 g |
| Ingress protection | IP00 |
| Recommended spark distance | 3–5 mm |
| Standard power cable length | 700 mm |
| Mounting feature | any position |
| Insulator material | PBT with 30% fiberglass |
| Electrical insulation | polyester resin |
| Secondary grounding | grounded in the center |
| Dust and moisture protection | IP00 |
| Number of outputs | 2 |
| Duration of ED(DU) operation | 33 % |
| High voltage outputs | 2 |
| Housing material | PBT with 30% fiberglass |
| Power supply | 220 V - 50 Hz |
| Terminal type | screw |
| Recommended electrode distance | 3 - 5 mm |
| Input effective current | 1.1 |
| Protection | IP00 |
| Default connection insulator | screw terminal |
| Number of poles | 2 |
| Protection class (IP) | IP00 |
| connection_type | screw terminal |
| Installation position | any position |
| Shape | shell |
| Secondary current | 20 mA |
| Duty cycle | 33% in 3 minutes |
| Net weight | 2 kg |
| Power consumption | 240 W |
| Frequency | 50 Hz |
455.20 EUR
413.82EUR
in stock · 2
incl. 21% VAT · 342.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma T16/MC ignition transformer (SKU 15360001) is designed for use in burners operating on liquid or gaseous fuels. It operates with a supply voltage of 220 V at 50 Hz, delivering a secondary voltage of 8 kV and a secondary current of 20 mA. The transformer has a duty cycle of 33% in 3 minutes, consumes 240 W, and weighs 2 kg. Its dimensions are 115 mm x 80 mm x 78 mm, and it features two high-voltage outputs with screw terminals. The housing is made of PBT with 30% fiberglass, and the insulation is polyester resin. The recommended spark distance is 3–5 mm, and the standard power cable length is 700 mm.
Further details
| Connector Options | screw, cylindrical terminal 4 mm or 6.3 mm |
|---|---|
| Construction Type | magnetic circuit in the form of a shell |
Choosing and fitting
When selecting a replacement ignition transformer of this type, ensure that the supply voltage, frequency, secondary voltage, and current ratings match the burner's requirements. The mounting system and electrical connection type (screw terminal) must be compatible with the existing setup. Verify the physical dimensions and weight to ensure proper fit. The transformer can be installed in any position, but the grounding must be securely connected to the system ground. Check the recommended electrode distance and cable length to match the application.
Signs of failure
Common failure modes for ignition transformers of this kind include internal short circuits, open windings, or insulation breakdown, leading to weak or no spark at the electrodes. Symptoms may include the burner failing to ignite, intermittent ignition, or a buzzing sound from the transformer. Check for visible damage, measure the secondary voltage with a suitable probe, and inspect the high-voltage cables and connections for wear or corrosion. Ensure the transformer is not overheating due to excessive duty cycle or poor ventilation.
All specifications
| Supply voltage | 220 V |
|---|---|
| Secondary voltage | 8 kV |
| Poles / outlets | 2 |
| Length | 115 mm |
| Width | 80 mm |
| Height | 78 mm |
| Body material | PBT with 30% fiberglass |
| Installation type | any position |
| Electrical connection | screw terminal |
| Dimensions | 11.5x8x7.8 cm |
| Weight | 2000 g |
| Ingress protection | IP00 |
| Recommended spark distance | 3–5 mm |
| Standard power cable length | 700 mm |
| Mounting feature | any position |
| Insulator material | PBT with 30% fiberglass |
| Electrical insulation | polyester resin |
| Secondary grounding | grounded in the center |
| Dust and moisture protection | IP00 |
| Number of outputs | 2 |
| Duration of ED(DU) operation | 33 % |
| High voltage outputs | 2 |
| Housing material | PBT with 30% fiberglass |
| Power supply | 220 V - 50 Hz |
| Terminal type | screw |
| Recommended electrode distance | 3 - 5 mm |
| Input effective current | 1.1 |
| Protection | IP00 |
| Default connection insulator | screw terminal |
| Number of poles | 2 |
| Protection class (IP) | IP00 |
| connection_type | screw terminal |
| Installation position | any position |
| Shape | shell |
| Secondary current | 20 mA |
| Duty cycle | 33% in 3 minutes |
| Net weight | 2 kg |
| Power consumption | 240 W |
| Frequency | 50 Hz |
Part numbers
| SKU | 15360001 |
|---|---|
| Additional article | 246.820.005 |
| Model | T16/MC |