{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Brahma Ignition transformer T16/MC 15360101

SKU 15360101 Model T16/MC Brand Brahma

Photos

Key specifications

Supply voltage220 V
Secondary voltage8–8 kV
Poles / outlets2
Length110 mm
Width96 mm
Height78 mm
Body materialpolyester resin
Installation typeany position
Ingress protectionIP00
Mounting featureany position
Electrical insulationpolyester resin
Secondary groundingcentrally grounded
Dust and moisture protectionIP00
Mounting and connecting systemsvarious
Current frequency50–50 Hz
Number of outputs2
Duration of ED(DU) operation33 %
High voltage outputs2
Power supply220 V - 50 Hz
ProtectionIP00
Protection class (IP)IP00
Installation positionany
Shapeshell
Radio interference suppression screenequipped
Default connection insulatorscrew terminal
Insulator material30% PBT glass fiber
Grounding pointsingle grounding center
High discharge powerhigh discharge power
High efficiencyhigh efficiency and ignition power
Weight2 g
Input effective current1.1
Output effective voltage2 kV
Number of poles2
Recommended spark distance3–5 mm
Standard power cable length700 mm
Dimensions11x9.6x7.8
Shielding deviceequipped to suppress radio interference
Ignition cable length reductionreduce to minimum
Cable routingseparate path near grounding planes
High voltage cables placementavoid near other cables
Suitable fuelsliquid or gaseous fuels
Long ignition wires suitableyes
Weight kg value2 kg
Poles count2
Recommended electrode distance3-5
Secondary current20 mA
Duty cycle33% in 3 minutes
Net weight2 kg
Power consumption240 W
Frequency50 Hz
all specifications (50) ↓
price on request
on order

shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

Brahma Ignition transformer T16/MC 15360101 is a shell-type spark transformer with a magnetic circuit, designed for burners using liquid or gaseous fuels. It operates at a supply voltage of 220 V and 50 Hz, delivering a secondary voltage of 8–8 kV with a secondary current of 20 mA. The transformer has two high-voltage outputs, a power consumption of 240 W, and a duty cycle of 33% in 3 minutes. It features polyester resin insulation, a centrally grounded secondary, and is equipped with a shielding device to suppress radio interference. The unit measures 110 mm in length, 96 mm in width, and 78 mm in height, with a net weight of 2 kg.

Further details

Coil capstwo caps painted with flame retardant paint
Construction Typespark transformer with magnetic circuit in the form of a shell
Designation meaningT (transformer), series of numbers, possibly letter for mounting system
Fire retardant capstwo caps painted with flame retardant paint
Identificationletter T, series of numbers, possibly letter for mounting system
Mounting system notationstandard mounting system no letter, different mounting system with letter
Mounting system standardno letter for standard, letter for different
Same characteristics different mountingmay have same electrical characteristics but different mounting system
Same electrical characteristicsmay have same electrical characteristics but different mounting system
Suitable for burnersburners with liquid or gaseous fuels

Choosing and fitting

When selecting an ignition transformer of this type, ensure the supply voltage, frequency, and secondary voltage/current ratings match the burner's requirements. The mounting system and connection type (e.g., screw terminal or cylindrical) must be compatible with the existing setup. The transformer can be installed in any position, but the ignition cable length should be minimized and routed away from other cables to reduce interference. Verify the recommended electrode distance (3–5 mm) and that the grounding is properly connected.

Signs of failure

Typical failures of ignition transformers include open or shorted windings, leading to weak or no spark at the electrodes. This may cause the burner to fail to ignite or to ignite intermittently. Check for visible damage, overheating, or signs of arcing on the high-voltage outputs. Also, verify the input voltage and continuity of the secondary circuit, as a faulty transformer may draw excessive current or produce no output.

Fits equipment

burners with liquid or gaseous fuels

All specifications

Supply voltage220 V
Secondary voltage8–8 kV
Poles / outlets2
Length110 mm
Width96 mm
Height78 mm
Body materialpolyester resin
Installation typeany position
Ingress protectionIP00
Mounting featureany position
Electrical insulationpolyester resin
Secondary groundingcentrally grounded
Dust and moisture protectionIP00
Mounting and connecting systemsvarious
Current frequency50–50 Hz
Number of outputs2
Duration of ED(DU) operation33 %
High voltage outputs2
Power supply220 V - 50 Hz
ProtectionIP00
Protection class (IP)IP00
Installation positionany
Shapeshell
Radio interference suppression screenequipped
Default connection insulatorscrew terminal
Insulator material30% PBT glass fiber
Grounding pointsingle grounding center
High discharge powerhigh discharge power
High efficiencyhigh efficiency and ignition power
Weight2 g
Input effective current1.1
Output effective voltage2 kV
Number of poles2
Recommended spark distance3–5 mm
Standard power cable length700 mm
Dimensions11x9.6x7.8
Shielding deviceequipped to suppress radio interference
Ignition cable length reductionreduce to minimum
Cable routingseparate path near grounding planes
High voltage cables placementavoid near other cables
Suitable fuelsliquid or gaseous fuels
Long ignition wires suitableyes
Weight kg value2 kg
Poles count2
Recommended electrode distance3-5
Secondary current20 mA
Duty cycle33% in 3 minutes
Net weight2 kg
Power consumption240 W
Frequency50 Hz

Part numbers

SKU15360101
Additional article246.820.070
ModelT16/MC