Brahma Ignition transformer T17/N 15453001
SKU 15453001
Model T17/N
Brand Brahma
Photos
Key specifications
| Supply voltage | 220 V |
|---|---|
| Secondary voltage | 4–4 kV |
| Poles / outlets | 2 |
| Body material | PBT with 30% fiberglass |
| Electrical insulation | polyester resin |
| Recommended spark distance | 3–5 mm |
| Standard power cable length | 550 mm |
| Secondary grounding | center grounded |
| RF shield grounding | must be securely grounded |
| Mounting feature | any position |
| Electrical connection | screw terminal |
| Operating phase | ignition phase |
| Input effective current | 0.6 |
| Two caps | yes |
| Secondary current | 15 mA |
| Duty cycle | 100% |
| Net weight | 2 kg |
| Power consumption | 140 W |
| Frequency | 50 Hz |
258.74 EUR
235.22EUR
in stock · 1
incl. 21% VAT · 194.40 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma T17/N ignition transformer (SKU 15453001) is designed for use in burners operating on liquid or gaseous fuels. It operates with a supply voltage of 220 V at 50 Hz, consuming 140 W. The transformer provides a secondary voltage of 4–4 kV with a secondary current of 15 mA, and features a 100% duty cycle. It has two poles, a net weight of 2 kg, and is constructed with a PBT body containing 30% fiberglass, with polyester resin insulation. The recommended spark distance is 3–5 mm, and the standard power cable length is 550 mm. The secondary winding is center grounded, and the RF shield must be securely grounded. The transformer can be mounted in any position and uses a screw terminal for electrical connection.
Further details
| Construction Type | magnetic circuit in the form of a shell |
|---|---|
| Fire Retardant Caps | two caps painted with flame retardant paint |
Choosing and fitting
When selecting an ignition transformer of this type, ensure that the supply voltage, frequency, and power consumption match the burner's electrical specifications. Verify the secondary voltage and current requirements, as well as the duty cycle, to ensure compatibility with the ignition system. The mounting system may vary; check the model designation for specific mounting features, and confirm the electrical connection type (e.g., screw terminal) matches the existing wiring. Measure the physical dimensions and weight to ensure proper fit within the equipment.
Signs of failure
Common failure modes for ignition transformers include insulation breakdown, which can cause short circuits or loss of spark. Symptoms may include the burner failing to ignite, intermittent ignition, or a weak spark. Check for visible damage to the body or cables, and test the secondary voltage and current with appropriate equipment. Ensure the ground connections are secure, as poor grounding can lead to erratic operation or interference.
All specifications
| Supply voltage | 220 V |
|---|---|
| Secondary voltage | 4–4 kV |
| Poles / outlets | 2 |
| Body material | PBT with 30% fiberglass |
| Electrical insulation | polyester resin |
| Recommended spark distance | 3–5 mm |
| Standard power cable length | 550 mm |
| Secondary grounding | center grounded |
| RF shield grounding | must be securely grounded |
| Mounting feature | any position |
| Electrical connection | screw terminal |
| Operating phase | ignition phase |
| Input effective current | 0.6 |
| Two caps | yes |
| Secondary current | 15 mA |
| Duty cycle | 100% |
| Net weight | 2 kg |
| Power consumption | 140 W |
| Frequency | 50 Hz |
Part numbers
| SKU | 15453001 |
|---|---|
| Additional article | 246.820.068 |
| Model | T17/N |