Brahma Ignition transformer T18 15510001
SKU 15510001
Model T18
Brand Brahma
Photos
Key specifications
| Supply voltage | 220 V |
|---|---|
| Poles / outlets | 2 |
| Length | 150 mm |
| Width | 101 mm |
| Height | 80 mm |
| Body material | pressed metal coated with enamel |
| Construction type | column-type transformers |
| Electrical insulation | polyester resin |
| Recommended spark distance | 3–5 mm |
| Standard power cable length | 700 mm |
| Input effective current | 0.9 |
| Ignition current | 16 mA |
| Winding configuration | 2 primary windings and 2 secondary windings |
| Vacuum cast polyester resin | yes |
| Ignition cable length reduction | yes |
| High voltage cables placement | avoid placing near other cables |
| Suitable for gas, diesel, oil | liquid or gaseous fuel |
| High discharge power | yes |
| Continuous operation | yes |
| Same dimensions, different characteristics | yes |
| Mounting systems variety | various connection and fastening systems |
| High voltage insulation | vacuum cast polyester resin |
| Enamel coating | yes |
| Identification letter | T |
| Model number | 18 |
| Standard fastening system | not indicated |
| Same characteristics, different mounting | possible |
| Rajah terminal insulators | available |
| Installation warning | dangerous voltage may be present |
| Disconnect before connecting | yes |
| Protection class (IP) | ensure appropriate degree of protection |
| Secondary current | 18 mA |
| Duty cycle | 100% |
| Net weight | 3.7 kg |
| Power consumption | 170 W |
| Frequency | 50 Hz |
271.52 EUR
246.84EUR
in stock · 2
incl. 21% VAT · 204.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma Ignition transformer T18 15510001 is a column-type transformer designed for continuous operation in ignition systems for liquid or gaseous fuel burners. It operates at a supply voltage of 220 V and 50 Hz, with a power consumption of 170 W. The transformer provides a secondary current of 18 mA and an ignition current of 16 mA, with a duty cycle of 100%. It features two primary and two secondary windings, insulated with vacuum-cast polyester resin, and has a pressed metal body coated with enamel. The unit measures 150 mm in length, 101 mm in width, and 80 mm in height, with a net weight of 3.7 kg.
Further details
| Additional letters for mounting system | sometimes letters related to specific mounting system |
|---|---|
| Cable Routing | route ignition cables along separate path close to ground planes |
| Example T8 | T8 refers to standard mounting system |
| Example T8/G | T8/G corresponds to different mounting system |
| Grounding requirement | transformer ground and electrical system ground well connected |
| Insulation Separator | special separator with high degree of insulation |
| Interference reduction | route cables close to ground planes |
| Parasitic capacitance note | reduce length of ignition cable to reduce parasitic capacitance |
Choosing and fitting
When selecting a replacement ignition transformer of this type, ensure that the supply voltage, frequency, and secondary current match the system requirements. The mounting system and dimensions must be compatible with the existing installation; various connection and fastening systems are available. Check the recommended spark distance (3–5 mm) and the standard power cable length (700 mm) to ensure proper fit. High voltage cables should be routed away from other cables to avoid interference, and the transformer must be disconnected from the power source before installation.
Signs of failure
Common failures in ignition transformers of this kind include insulation breakdown leading to short circuits or open windings, which may result in weak or no spark at the electrodes. Symptoms on the equipment include ignition failure, intermittent burner operation, or a noticeable drop in spark intensity. Check the transformer for signs of overheating, enamel damage, or cracks in the resin insulation, and verify the output voltage and current with appropriate test equipment.
All specifications
| Supply voltage | 220 V |
|---|---|
| Poles / outlets | 2 |
| Length | 150 mm |
| Width | 101 mm |
| Height | 80 mm |
| Body material | pressed metal coated with enamel |
| Construction type | column-type transformers |
| Electrical insulation | polyester resin |
| Recommended spark distance | 3–5 mm |
| Standard power cable length | 700 mm |
| Input effective current | 0.9 |
| Ignition current | 16 mA |
| Winding configuration | 2 primary windings and 2 secondary windings |
| Vacuum cast polyester resin | yes |
| Ignition cable length reduction | yes |
| High voltage cables placement | avoid placing near other cables |
| Suitable for gas, diesel, oil | liquid or gaseous fuel |
| High discharge power | yes |
| Continuous operation | yes |
| Same dimensions, different characteristics | yes |
| Mounting systems variety | various connection and fastening systems |
| High voltage insulation | vacuum cast polyester resin |
| Enamel coating | yes |
| Identification letter | T |
| Model number | 18 |
| Standard fastening system | not indicated |
| Same characteristics, different mounting | possible |
| Rajah terminal insulators | available |
| Installation warning | dangerous voltage may be present |
| Disconnect before connecting | yes |
| Protection class (IP) | ensure appropriate degree of protection |
| Secondary current | 18 mA |
| Duty cycle | 100% |
| Net weight | 3.7 kg |
| Power consumption | 170 W |
| Frequency | 50 Hz |
Part numbers
| SKU | 15510001 |
|---|---|
| Additional article | 246.820.006 |
| Model | T18 |