{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Brahma Ignition transformer T8 15000081

SKU 15000081 Model T8 Brand Brahma

Photos

Key specifications

Supply voltage220 V
Poles / outlets2
Length101 mm
Width80 mm
Height150 mm
Body materialpressed metal coated with enamel
Construction typecolumn-type transformers
Dimensions10.1x8x15 cm
Weight3500 g
Standard power cable length700 mm
Electrical insulationpolyester resin
Ignition current35 mA
Input effective current2.1
Protectionip 00
Number of poles2
Protection class (IP)ip 00
Secondary current33 mA
Duty cycle33% in 3 minutes
Net weight3.5 kg
Power consumption460 W
Frequency50 Hz
all specifications (21) ↓
360.17 EUR
327.43EUR
in stock · 2

incl. 21% VAT · 270.60 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Brahma T8 ignition transformer (SKU 15000081) is a column-type transformer with a pressed metal body coated with enamel and polyester resin insulation. It operates on a 220 V, 50 Hz supply, consuming 460 W, with an input effective current of 2.1 A. The transformer provides a secondary current of 33 mA and an ignition current of 35 mA, with a duty cycle of 33% in 3 minutes. It has 2 poles, measures 101x80x150 mm (10.1x8x15 cm), weighs 3.5 kg, and includes a standard power cable length of 700 mm. The protection class is IP 00.

Further details

Winding Configurationtwo primary windings and two secondary windings

Choosing and fitting

Parts of this type are selected by matching the supply voltage, frequency, and mounting system to the burner's requirements. The transformer's dimensions and mounting configuration must align with the existing bracket or enclosure. Ensure the secondary current and ignition current are compatible with the electrode gap and ignition system. The standard power cable length and connector type (screw or 6.3 mm terminal) should be verified for proper connection.

Signs of failure

When such transformers fail, common symptoms include weak or no spark at the electrodes, intermittent ignition, or tripping of the burner's safety lockout. Failure may result from insulation breakdown, shorted windings, or moisture ingress due to low IP rating. Check for visible damage, measure primary and secondary voltages, and inspect the high-voltage cables for cracks or loose connections.

All specifications

Supply voltage220 V
Poles / outlets2
Length101 mm
Width80 mm
Height150 mm
Body materialpressed metal coated with enamel
Construction typecolumn-type transformers
Dimensions10.1x8x15 cm
Weight3500 g
Standard power cable length700 mm
Electrical insulationpolyester resin
Ignition current35 mA
Input effective current2.1
Protectionip 00
Number of poles2
Protection class (IP)ip 00
Secondary current33 mA
Duty cycle33% in 3 minutes
Net weight3.5 kg
Power consumption460 W
Frequency50 Hz

Part numbers

SKU15000081
Additional article246.820.112
ModelT8