Key specifications
| Supply voltage | 220 V |
|---|---|
| Poles / outlets | 2 |
| Length | 101 mm |
| Width | 80 mm |
| Height | 150 mm |
| Body material | pressed metal coated with enamel |
| Construction type | column-type transformers |
| Dimensions | 10.1x8x15 cm |
| Weight | 3500 g |
| Standard power cable length | 700 mm |
| Electrical insulation | polyester resin |
| Ignition current | 35 mA |
| Input effective current | 2.1 |
| Protection | ip 00 |
| Number of poles | 2 |
| Protection class (IP) | ip 00 |
| Secondary current | 33 mA |
| Duty cycle | 33% in 3 minutes |
| Net weight | 3.5 kg |
| Power consumption | 460 W |
| Frequency | 50 Hz |
360.17 EUR
327.43EUR
in stock · 2
incl. 21% VAT · 270.60 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma T8 ignition transformer (SKU 15000081) is a column-type transformer with a pressed metal body coated with enamel and polyester resin insulation. It operates on a 220 V, 50 Hz supply, consuming 460 W, with an input effective current of 2.1 A. The transformer provides a secondary current of 33 mA and an ignition current of 35 mA, with a duty cycle of 33% in 3 minutes. It has 2 poles, measures 101x80x150 mm (10.1x8x15 cm), weighs 3.5 kg, and includes a standard power cable length of 700 mm. The protection class is IP 00.
Further details
| Winding Configuration | two primary windings and two secondary windings |
|---|
Choosing and fitting
Parts of this type are selected by matching the supply voltage, frequency, and mounting system to the burner's requirements. The transformer's dimensions and mounting configuration must align with the existing bracket or enclosure. Ensure the secondary current and ignition current are compatible with the electrode gap and ignition system. The standard power cable length and connector type (screw or 6.3 mm terminal) should be verified for proper connection.
Signs of failure
When such transformers fail, common symptoms include weak or no spark at the electrodes, intermittent ignition, or tripping of the burner's safety lockout. Failure may result from insulation breakdown, shorted windings, or moisture ingress due to low IP rating. Check for visible damage, measure primary and secondary voltages, and inspect the high-voltage cables for cracks or loose connections.
All specifications
| Supply voltage | 220 V |
|---|---|
| Poles / outlets | 2 |
| Length | 101 mm |
| Width | 80 mm |
| Height | 150 mm |
| Body material | pressed metal coated with enamel |
| Construction type | column-type transformers |
| Dimensions | 10.1x8x15 cm |
| Weight | 3500 g |
| Standard power cable length | 700 mm |
| Electrical insulation | polyester resin |
| Ignition current | 35 mA |
| Input effective current | 2.1 |
| Protection | ip 00 |
| Number of poles | 2 |
| Protection class (IP) | ip 00 |
| Secondary current | 33 mA |
| Duty cycle | 33% in 3 minutes |
| Net weight | 3.5 kg |
| Power consumption | 460 W |
| Frequency | 50 Hz |
Part numbers
| SKU | 15000081 |
|---|---|
| Additional article | 246.820.112 |
| Model | T8 |