Brahma Ignition transformer TC1LTCAF 15910407
SKU 15910407
Model TC1LTCAF
Brand Brahma
Photos
Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Secondary voltage | 15 kV |
| Poles / outlets | 1 |
| Construction type | high-frequency electronic generator |
| Operating principle | step-up transformer |
| Maximum length of ignition cable with integrated electronic ignition | 1.5 m |
| Rated current (mA) | 20 mA |
| Peak current (mA) | 45 mA |
| Recommended spark distance | 3–5 mm |
| Standard power cable length | 560 mm |
| Output voltage frequency | 6–10 kHz |
| Protection | IP00 |
| Core material | ferritic |
| Built-in varistor | yes |
| Overload protection | yes |
| Mounting screw | M4x45 |
| Power cable options | built-in power cable or connector |
| Connector availability | available on request |
| Compact design | highly compact |
| Light weight | light weight |
| High efficiency | high efficiency and ignition power |
| Mounting and connecting systems | various mounting and connecting systems |
| Complies with directive | 2004/108/ec |
| Low voltage directive | 73/23/eec |
| Output voltage max | 15 kV |
| Application scope | domestic, commercial and industrial installations |
| Mounting systems variety | various mounting and connecting systems |
| Ferritic core | yes |
| High-frequency generator | yes |
| Ignition power | high |
| Protection class (IP) | IP00 |
| Weight (approx) | about 420 g |
| Secondary current | 20 mA |
| Duty cycle | 50 % |
| Net weight | 0.42 kg |
| Power consumption | 45 W |
| Frequency | 50–60 Hz |
—price on request
on order
shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma TC1LTCAF ignition transformer (SKU 15910407) is a high-frequency electronic generator that steps up voltage via a ferritic-core transformer to deliver a secondary voltage of 15 kV and a secondary current of 20 mA. It operates on a 220–240 V supply at 50–60 Hz, consuming 45 W, with a duty cycle of 50%. The transformer features a single pole, a peak current of 45 mA, and an output voltage frequency of 6–10 kHz. It is designed for domestic, commercial, and industrial burner applications, offering a compact and lightweight construction with built-in varistor and overload protection. The unit complies with directives 2004/108/EC and 73/23/EEC, and has an IP00 protection rating.
Further details
| Design Features | compact dimensions and low weight with high ignition power |
|---|---|
| Imq Resolution | EN 61558-1:1997 + A1:1998 +A11:2003 and EN 61558-2-3:2000 |
| Safety Standard | EN 61558-1:1997 + A1:1998 +A11:2003 and EN 61558-2-3:2000 |
| Single Or Double Pin Output | single or double-pin high voltage output |
| Suitable For Gas Diesel Oil | gas burners and burners with light and heavy types of liquid fuels |
| Thermal Compound | special composition with high thermal conductivity and special expansion coefficient |
Choosing and fitting
When selecting an ignition transformer of this type, ensure the supply voltage, frequency, and secondary voltage/current ratings match the burner controller's requirements. Verify the mounting screw size (e.g., M4x45) and the type of high-voltage connection (threaded or Ø4 mm connector) to fit the existing assembly. The maximum ignition cable length and recommended spark distance must be compatible with the electrode setup. Power cable options include built-in cable or connector, with connector availability on request.
Signs of failure
Typical failures of such ignition transformers include internal short circuits or open windings, often caused by overheating or voltage surges, leading to weak or no spark at the electrode. The equipment may fail to ignite, produce intermittent sparks, or trip the controller. Check for visible damage, measure secondary voltage with a suitable probe, and verify the varistor and overload protection functions.
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Secondary voltage | 15 kV |
| Poles / outlets | 1 |
| Construction type | high-frequency electronic generator |
| Operating principle | step-up transformer |
| Maximum length of ignition cable with integrated electronic ignition | 1.5 m |
| Rated current (mA) | 20 mA |
| Peak current (mA) | 45 mA |
| Recommended spark distance | 3–5 mm |
| Standard power cable length | 560 mm |
| Output voltage frequency | 6–10 kHz |
| Protection | IP00 |
| Core material | ferritic |
| Built-in varistor | yes |
| Overload protection | yes |
| Mounting screw | M4x45 |
| Power cable options | built-in power cable or connector |
| Connector availability | available on request |
| Compact design | highly compact |
| Light weight | light weight |
| High efficiency | high efficiency and ignition power |
| Mounting and connecting systems | various mounting and connecting systems |
| Complies with directive | 2004/108/ec |
| Low voltage directive | 73/23/eec |
| Output voltage max | 15 kV |
| Application scope | domestic, commercial and industrial installations |
| Mounting systems variety | various mounting and connecting systems |
| Ferritic core | yes |
| High-frequency generator | yes |
| Ignition power | high |
| Protection class (IP) | IP00 |
| Weight (approx) | about 420 g |
| Secondary current | 20 mA |
| Duty cycle | 50 % |
| Net weight | 0.42 kg |
| Power consumption | 45 W |
| Frequency | 50–60 Hz |
Part numbers
| SKU | 15910407 |
|---|---|
| Additional article | 246.820.033 |
| Model | TC1LTCAF |