Brahma Ignition transformer TC1LVCA 15911000

SKU 15911000 Model TC1LVCA Brand Brahma

Photos

Key specifications

Supply voltage220–240 V
Secondary voltage15 kV
Poles / outlets1
Construction typehigh-frequency electronic generator
Maximum length of ignition cable with integrated electronic ignition1.5 m
Standard power cable length560 mm
Recommended spark distance3–5 mm
Peak current (mA)45 mA
Output voltage frequency6–10 kHz
Ingress protectionip00
Number of contacts1
Core materialferritic core
Short-circuit protectionbuilt-in
Varistor protectionbuilt-in varistor
Protection against temperature fluctuationsspecial compound
High efficiencyhigh efficiency and ignition power
Compact designcompact dimensions
Light weightlow weight
High-frequency generatorhigh-frequency electronic generator
Ferritic coreferritic core
Mounting and connecting systemsvarious mounting and connecting systems
Protection class (IP)ip00
Protectionip00
Output voltage max15 kV
Peak voltage15 kV
Varistor protectionbuilt-in varistor
Secondary current45 mA
Duty cycle50 %
Net weight0.42 kg
Power consumption25 W
Frequency50–60 Hz
all specifications (31) ↓
67.88 EUR
61.71EUR
in stock · 40

incl. 21% VAT · 51.00 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Brahma TC1LVCA ignition transformer (SKU 15911000) is a high-frequency electronic generator with a ferritic core, designed for gas and liquid fuel burners. It operates on a supply voltage of 220–240 V at 50–60 Hz, consuming 25 W. The transformer delivers a secondary voltage of 15 kV with a secondary current of 45 mA, and an output voltage frequency of 6–10 kHz. It features a single pole, built-in short circuit protection, and a varistor for surge protection. The unit weighs 0.42 kg and has an ingress protection rating of IP00.

Further details

Application Scopegas burners, light and heavy liquid fuel burners
Thermal Compoundspecial compound with high thermal conductivity and special expansion coefficient

Choosing and fitting

When selecting an ignition transformer of this type, ensure the supply voltage, frequency, and power consumption match the burner's electrical specifications. Verify the secondary voltage and current requirements of the ignition electrode, as well as the maximum ignition cable length (1.5 m) and standard power cable length (560 mm). The recommended spark distance is 3–5 mm. Mounting and connecting systems vary, so confirm the physical dimensions and contact configuration (number of poles) fit the burner's design. The duty cycle (50%) must be compatible with the burner's operational cycle.

Signs of failure

Typical failures of ignition transformers include internal short circuits, open circuits, or breakdown of insulation, often due to moisture or overheating. Symptoms on the equipment include weak or no spark at the electrode, intermittent ignition, or burner lockout. Check the secondary voltage and current output with appropriate test equipment, inspect the ignition cable for damage, and verify the spark gap is within the recommended range. Also, ensure the supply voltage is stable and within specifications, as surges can damage the internal varistor.

All specifications

Supply voltage220–240 V
Secondary voltage15 kV
Poles / outlets1
Construction typehigh-frequency electronic generator
Maximum length of ignition cable with integrated electronic ignition1.5 m
Standard power cable length560 mm
Recommended spark distance3–5 mm
Peak current (mA)45 mA
Output voltage frequency6–10 kHz
Ingress protectionip00
Number of contacts1
Core materialferritic core
Short-circuit protectionbuilt-in
Varistor protectionbuilt-in varistor
Protection against temperature fluctuationsspecial compound
High efficiencyhigh efficiency and ignition power
Compact designcompact dimensions
Light weightlow weight
High-frequency generatorhigh-frequency electronic generator
Ferritic coreferritic core
Mounting and connecting systemsvarious mounting and connecting systems
Protection class (IP)ip00
Protectionip00
Output voltage max15 kV
Peak voltage15 kV
Varistor protectionbuilt-in varistor
Secondary current45 mA
Duty cycle50 %
Net weight0.42 kg
Power consumption25 W
Frequency50–60 Hz

Part numbers

SKU15911000
Additional article246.820.059
ModelTC1LVCA