{# Разметка для пересылки ссылки. Заголовок и описание по умолчанию берутся из тех же блоков, что и обычные: раньше на каталоге, разделах и карточках тут стояло голое «kroms» и пустое описание. #}

Brahma Ignition transformer TC1LVCAF 15910400

SKU 15910400 Model TC1LVCAF Brand Brahma

Photos

Key specifications

Supply voltage220–240 V
Secondary voltage15 kV
Poles / outlets1
Construction typeelectronic with ferritic core
Maximum length of ignition cable with integrated electronic ignition1.5 m
Standard power cable length560 mm
Peak current (mA)45 mA
Rated current (mA)20 mA
Recommended spark distance3–5 mm
Output voltage frequency6–10 kHz
Output voltage max15 kV
Built-in filteravailable
Compact designextremely compact overall dimensions
High efficiencyhigh efficiency and ignition power
Mounting and connecting systemsvarious mounting and connecting systems
Short-circuit protectionbuilt-in short circuit protection
Low voltage directive73/23/eec
Ferritic coretransformer with a ferritic core
Light weightlight weight and compact size
Overload protectionprotection against overloads
Connector availabilityavailable on request
Complies with directive2004/108/ec
Output typesingle or double-pin
Power cable optionsbuilt-in power cable or connector
Electromagnetic interference protectionbuilt-in filter reduces electromagnetic interference
High voltage insulationinsulator for high-voltage cable
Compatible componentsBrahma controllers
Secondary current20 mA
Duty cycleavailable
Net weight0.42 kg
Power consumptionlow power consumption
Frequency50–60 Hz
all specifications (32) ↓
67.88 EUR
61.71EUR
in stock · 3

incl. 21% VAT · 51.00 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

The Brahma TC1LVCAF ignition transformer (SKU 15910400) is an electronic device with a ferritic core, designed for gas and liquid fuel burners in domestic, commercial, and industrial installations. It operates on a supply voltage of 220–240 V at 50–60 Hz, producing a maximum output voltage of 15 kV with a rated secondary current of 20 mA and a peak current of 45 mA. The output voltage frequency ranges from 6 to 10 kHz, and the recommended spark distance is 3–5 mm. It features a built-in filter to reduce electromagnetic interference, short-circuit and overload protection, and complies with directives 73/23/EEC and 2004/108/EC. The transformer has a single pole, weighs 0.42 kg, and supports an ignition cable up to 1.5 m in length, with a standard power cable of 560 mm.

Further details

Application scopegas burners, burners for light and heavy types of liquid fuels in domestic, commercial, industrial installations
High-frequency generatorbased on a high-frequency electronic generator
IMQ resolutionin accordance with standards en 61558-1:1997 + a1:1998 +a11:2003 and en 61558-2- 3:2000
Installation typedirectly on transformer with M4x45 screws
Operating principlehigh-frequency electronic generator increases voltage via ferritic core transformer
Protection against temperature fluctuationsprotection against temperature fluctuations and overloads
Safety standardEN 61558-1:1997 + A1:1998 +A11:2003 and EN 61558-2-3:2000
Single or double-pin high voltage outputsingle or double-pin high voltage output
Thermal compoundspecial compound with high thermal conductivity and a special expansion coefficient
Varistor protectionbuilt-in varistor protects against power surges

Choosing and fitting

When selecting an ignition transformer of this type, verify that the supply voltage, frequency, and output voltage match the burner's requirements. Check the mounting and connecting systems, as these transformers offer various options, including single or double-pin high-voltage output and built-in power cable or connector. Ensure the high-voltage cable length does not exceed the maximum specified for the model, and confirm the spark distance is set correctly. The transformer can be used with compatible Brahma controllers, which may be mounted directly using M4x45 screws.

Signs of failure

Typical failures of this kind of ignition transformer include loss of spark or weak spark, often caused by internal short circuits or overloads. The equipment may fail to ignite or exhibit intermittent ignition. Check for visible damage, ensure the spark gap is within the recommended range, and verify that the supply voltage is stable. If the transformer has a built-in filter, electromagnetic interference issues may indicate a fault.

All specifications

Supply voltage220–240 V
Secondary voltage15 kV
Poles / outlets1
Construction typeelectronic with ferritic core
Maximum length of ignition cable with integrated electronic ignition1.5 m
Standard power cable length560 mm
Peak current (mA)45 mA
Rated current (mA)20 mA
Recommended spark distance3–5 mm
Output voltage frequency6–10 kHz
Output voltage max15 kV
Built-in filteravailable
Compact designextremely compact overall dimensions
High efficiencyhigh efficiency and ignition power
Mounting and connecting systemsvarious mounting and connecting systems
Short-circuit protectionbuilt-in short circuit protection
Low voltage directive73/23/eec
Ferritic coretransformer with a ferritic core
Light weightlight weight and compact size
Overload protectionprotection against overloads
Connector availabilityavailable on request
Complies with directive2004/108/ec
Output typesingle or double-pin
Power cable optionsbuilt-in power cable or connector
Electromagnetic interference protectionbuilt-in filter reduces electromagnetic interference
High voltage insulationinsulator for high-voltage cable
Compatible componentsBrahma controllers
Secondary current20 mA
Duty cycleavailable
Net weight0.42 kg
Power consumptionlow power consumption
Frequency50–60 Hz

Part numbers

SKU15910400
Additional article246.820.040
ModelTC1LVCAF