Brahma Ignition transformer TC1STPAF 15910504
SKU 15910504
Model TC1STPAF
Brand Brahma
Photos
Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Secondary voltage | 15 kV |
| Poles / outlets | 1 |
| Construction type | electronic |
| Maximum length of ignition cable with integrated electronic ignition | 1.5 m |
| Standard power cable length | 560 mm |
| Recommended spark distance | 3–5 mm |
| Peak current (mA) | 45 mA |
| Rated current (mA) | 20 mA |
| Output voltage frequency | 6 kHz |
| Protection class (IP) | IP00 |
| Ingress protection | IP00 |
| Technology | high-frequency electronic |
| Core material | ferritic core |
| Built-in filter | integrated EMC filter |
| Short-circuit protection | built-in short circuit protection |
| High efficiency | high efficiency and ignition power |
| Light weight | light weight and compact size |
| Mounting and connecting systems | various fastening and connecting systems |
| Output voltage max | 15 kV |
| Operating phase | ignition phase |
| Electromagnetic interference protection | filter to reduce electromagnetic interference |
| Complies with directive | 2004/108/ec |
| EMC filter standard | 2004/108/ec |
| External filter not required | no additional external filters required |
| Operation mode | continuous operation (100% duty cycle) |
| Working cycle duration | 50% |
| Cycle type | 50% |
| Suitable for gas, diesel, oil | gas and liquid fuel burners |
| Fuel | gas and liquid fuel |
| Compact size | compact in size |
| High-frequency generator | high-frequency electronic generator |
| Ferritic core | ferritic core |
| High voltage outputs | 1 |
| Number of outputs | 1 |
| Number of poles | 1 |
| Poles count | 1 |
| Peak voltage | 15 kV |
| Energy consumption | 45 VA |
| Input voltage range | 220-240 V |
| Power supply | 220-240 V |
| Protection | IP00 |
| Dust and moisture protection | IP00 |
| Housing protection | IP00 |
| Sealed housing | IP00 |
| Shock-resistant housing | IP00 |
| Housing type | compact |
| Operating principle | step-up transformer |
| Function | ignition transformer |
| Device type | ignition transformer |
| Transformer type | ignition transformer |
| Catalogue article numbers | 15910504, 246.820.075 |
| Warehouse part number | 246.820.075 |
| Manufacturer part number | 15910504 |
| Designation | TC1STPAF |
| Short name | Brahma 15910504 TC1STPAF ignition transformer |
| Name (English) | Brahma 15910504 TC1STPAF ignition transformer |
| SKU (English) | 15910504, 246.820.075 |
| Weight (approx) | about 420 g |
| Weight kg value | 0.42 kg |
| Weight | 420 g |
| Mounting systems variety | various fastening and connecting systems |
| Standard fastening system | various fastening and connecting systems |
| Mounting arrangement | various fastening and connecting systems |
| Mounting type | various fastening and connecting systems |
| Mounting feature | various fastening and connecting systems |
| Power cable length included | 560 mm |
| Max power cable length | 1.5 m |
| Secondary current | 20 mA |
| Duty cycle | 50% |
| Net weight | 0.42 kg |
| Gross weight | 0.42 kg |
| Power consumption | 45 W |
| Frequency | 50 Hz |
67.88 EUR
61.71EUR
in stock · 2
incl. 21% VAT · 51.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma TC1STPAF 15910504 is a high-frequency electronic ignition transformer designed for gas and liquid fuel burners. It operates on a 220–240 V supply at 50 Hz, consuming 45 W, and delivers a secondary voltage of 15 kV with a rated current of 20 mA and a peak current of 45 mA. The transformer features a ferritic core, integrated EMC filter, and built-in short circuit protection, with an IP00 protection class. It has a duty cycle of 50%, a recommended spark distance of 3–5 mm, and supports an ignition cable up to 1.5 m in length. The unit is compact and lightweight, weighing 0.42 kg, and includes a standard power cable of 560 mm.
Further details
| Application Scope | gas and liquid fuel burners, including domestic, commercial and industrial installations |
|---|---|
| Continuous Operation | versions for continuous operation (100% duty cycle) |
| Installation Type | designed for use in gas and liquid fuel burners |
| Operating Principle | high-frequency electronic generator increases voltage using a transformer with a ferritic core |
| Output Type | single or two-pin high voltage output |
| Single Or Double Contact | single or two-pin high voltage output |
Choosing and fitting
When selecting an ignition transformer of this type, ensure the supply voltage, frequency, and power consumption match the burner's electrical system. Verify the secondary voltage and current ratings are compatible with the ignition electrode and cable length. The transformer must have the correct number of high-voltage outputs (single or two-pin) and mounting arrangement to fit the burner. Check the protection class and duty cycle to ensure suitability for the operating environment and ignition cycle.
Signs of failure
Common failure modes for ignition transformers include internal short circuits, open windings, or breakdown of insulation, leading to weak or no spark. Symptoms may include the burner failing to ignite, intermittent ignition, or visible arcing or burning at the high-voltage output. Check for proper supply voltage, continuity of the ignition cable, and signs of overheating or damage to the transformer housing.
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Secondary voltage | 15 kV |
| Poles / outlets | 1 |
| Construction type | electronic |
| Maximum length of ignition cable with integrated electronic ignition | 1.5 m |
| Standard power cable length | 560 mm |
| Recommended spark distance | 3–5 mm |
| Peak current (mA) | 45 mA |
| Rated current (mA) | 20 mA |
| Output voltage frequency | 6 kHz |
| Protection class (IP) | IP00 |
| Ingress protection | IP00 |
| Technology | high-frequency electronic |
| Core material | ferritic core |
| Built-in filter | integrated EMC filter |
| Short-circuit protection | built-in short circuit protection |
| High efficiency | high efficiency and ignition power |
| Light weight | light weight and compact size |
| Mounting and connecting systems | various fastening and connecting systems |
| Output voltage max | 15 kV |
| Operating phase | ignition phase |
| Electromagnetic interference protection | filter to reduce electromagnetic interference |
| Complies with directive | 2004/108/ec |
| EMC filter standard | 2004/108/ec |
| External filter not required | no additional external filters required |
| Operation mode | continuous operation (100% duty cycle) |
| Working cycle duration | 50% |
| Cycle type | 50% |
| Suitable for gas, diesel, oil | gas and liquid fuel burners |
| Fuel | gas and liquid fuel |
| Compact size | compact in size |
| High-frequency generator | high-frequency electronic generator |
| Ferritic core | ferritic core |
| High voltage outputs | 1 |
| Number of outputs | 1 |
| Number of poles | 1 |
| Poles count | 1 |
| Peak voltage | 15 kV |
| Energy consumption | 45 VA |
| Input voltage range | 220-240 V |
| Power supply | 220-240 V |
| Protection | IP00 |
| Dust and moisture protection | IP00 |
| Housing protection | IP00 |
| Sealed housing | IP00 |
| Shock-resistant housing | IP00 |
| Housing type | compact |
| Operating principle | step-up transformer |
| Function | ignition transformer |
| Device type | ignition transformer |
| Transformer type | ignition transformer |
| Catalogue article numbers | 15910504, 246.820.075 |
| Warehouse part number | 246.820.075 |
| Manufacturer part number | 15910504 |
| Designation | TC1STPAF |
| Short name | Brahma 15910504 TC1STPAF ignition transformer |
| Name (English) | Brahma 15910504 TC1STPAF ignition transformer |
| SKU (English) | 15910504, 246.820.075 |
| Weight (approx) | about 420 g |
| Weight kg value | 0.42 kg |
| Weight | 420 g |
| Mounting systems variety | various fastening and connecting systems |
| Standard fastening system | various fastening and connecting systems |
| Mounting arrangement | various fastening and connecting systems |
| Mounting type | various fastening and connecting systems |
| Mounting feature | various fastening and connecting systems |
| Power cable length included | 560 mm |
| Max power cable length | 1.5 m |
| Secondary current | 20 mA |
| Duty cycle | 50% |
| Net weight | 0.42 kg |
| Gross weight | 0.42 kg |
| Power consumption | 45 W |
| Frequency | 50 Hz |
Part numbers
| SKU | 15910504 |
|---|---|
| Additional article | 246.820.075 |
| Model | TC1STPAF |