Brahma Ignition transformer TC2LVCS 15911301

SKU 15911301 Model TC2LVCS Brand Brahma

Photos

Key specifications

Supply voltage110-120 V 50/60 Hz
Construction typehigh-frequency electronic
Peak voltage12 kV
Peak current (mA)55 mA
Output voltage frequency8.5–12 kHz
Number of contacts2
Operating temperature-10–60 °C
Ingress protectionIP00
Recommended spark distance3–5 mm
Maximum length of ignition cable with integrated electronic ignition1.5 m
Standard power cable length560 mm
Core materialferritic core
Varistor protectionbuilt-in varistor
Safety featurebuilt-in short circuit protection
Duty cycle100%
Net weight0.42 kg
Power consumption30 W
Frequency50–60 Hz
all specifications (18) ↓
67.88 EUR
61.71EUR
in stock · 2

incl. 21% VAT · 51.00 EUR excl. VAT · shipping calculated at checkout

  • Worldwide shipping from stock
  • Original manufacturer part
  • Dispatch within 24 h for stocked items

Description

This high-frequency electronic ignition transformer has a ferritic core and is intended for use in gas and liquid fuel burners. It operates from a 110-120 V AC supply at 50/60 Hz, consumes 30 W, and produces a peak voltage of 12 kV at a peak current of 55 mA with an output frequency of 8.5-12 kHz. The unit has two contacts and is rated for continuous operation (100% duty cycle) over a temperature range of -10 to 60 °C. It features IP00 protection, a built-in varistor, and short-circuit protection. The transformer is supplied with a 560 mm power cable; the maximum ignition cable length is 1.5 m, and the recommended spark distance is 3-5 mm. The net weight is 0.42 kg.

Further details

Built In Filteravailable as option (integrated EMC filter)
CertificationIMQ certificate in accordance with EN 61558-1 and EN 61558-2-3; Low Voltage Directive 73/23/EEC
Connector Optionsdifferent number and position of contacts, types of high-voltage connections and power cable, with/without EMC filter
Cycle Typenon-permanent version: 50% duty cycle in 2 minutes
Thermal Compoundspecial compound with high thermal conductivity and special expansion coefficient

Choosing and fitting

When selecting a replacement ignition transformer, match the supply voltage, the number and arrangement of high-voltage contacts, the type of high-voltage connection, and the mounting configuration to the original unit. These transformers may have single or double-pin outputs and different power cable connectors; also check whether the application requires an integrated EMC filter. Install the new transformer using the correct wiring diagram, and set the spark electrode gap and ignition cable length according to the manufacturer's specifications.

All specifications

Supply voltage110-120 V 50/60 Hz
Construction typehigh-frequency electronic
Peak voltage12 kV
Peak current (mA)55 mA
Output voltage frequency8.5–12 kHz
Number of contacts2
Operating temperature-10–60 °C
Ingress protectionIP00
Recommended spark distance3–5 mm
Maximum length of ignition cable with integrated electronic ignition1.5 m
Standard power cable length560 mm
Core materialferritic core
Varistor protectionbuilt-in varistor
Safety featurebuilt-in short circuit protection
Duty cycle100%
Net weight0.42 kg
Power consumption30 W
Frequency50–60 Hz

Part numbers

SKU15911301
Additional article246.820.058
ModelTC2LVCS