Brahma Ignition transformer TC2STCAF 15910551
SKU 15910551
Model TC2STCAF
Brand Brahma
Photos
Key specifications
| Supply voltage | 220–240 V |
|---|---|
| Secondary voltage | 24 kV |
| Poles / outlets | 2 |
| Maximum length of ignition cable with integrated electronic ignition | 1.5 m |
| Standard power cable length | 560 mm |
| Recommended spark distance | 3–5 mm |
| Output voltage frequency | 6 kHz |
| Rated current (mA) | 27 mA |
| Ingress protection | IP00 |
| Output voltage max | 15 kV |
| Built-in filter | integrated EMC filter |
| Short-circuit protection | built-in |
| Varistor protection | built-in varistor |
| High-frequency generator | high-frequency electronic generator |
| Ferritic core | ferritic core |
| Mounting screw | M4x45 screws |
| Compatible controllers | Brahma controllers |
| Low voltage directive | 73/23/EEC |
| Electromagnetic interference protection | filter to reduce electromagnetic interference |
| External filter not required | no additional external filters required |
| Continuous operation | 100% duty cycle |
| Light weight | light weight |
| Compact size | compact size |
| High efficiency | high efficiency and ignition power |
| Mounting and connecting systems | various mounting and connecting systems |
| Installation ease | ease of installation |
| Maintenance requirement | ease of maintenance |
| Reliability | reliable operation |
| Certification | IMQ resolution |
| Safety standard | low voltage directive (LVD) 73/23/EEC |
| Secondary current | 55 mA |
| Duty cycle | 50 % |
| Net weight | 0.42 kg |
| Power consumption | low power consumption |
| Frequency | 50 Hz |
67.88 EUR
61.71EUR
in stock · 4
incl. 21% VAT · 51.00 EUR excl. VAT · shipping calculated at checkout
- Worldwide shipping from stock
- Original manufacturer part
- Dispatch within 24 h for stocked items
Description
The Brahma Ignition transformer TC2STCAF 15910551 is a compact device designed for gas and liquid fuel burners. It operates on a 220–240 V supply at 50 Hz, with a secondary voltage of 24 kV and a secondary current of 55 mA. The transformer features a high-frequency electronic generator and a ferritic core, delivering an output voltage up to 15 kV. It has a duty cycle of 50%, a rated current of 27 mA, and an output voltage frequency of 6 kHz. The unit includes an integrated EMC filter, built-in short circuit protection, and a varistor for surge protection. It weighs 0.42 kg and is certified to IMQ resolution and low voltage directive 73/23/EEC.
Further details
| Application scope | gas burners, burners for light and heavy liquid fuels, domestic, commercial, industrial |
|---|---|
| Connector availability | various types of connectors, including connectors with cable, on request |
| Durability | stable operation under various temperature conditions |
| IMQ resolution | EN 61558-1:1997 + A1:1998 +A11:2003 and EN 61558-2-3:2000 |
| Protection against temperature fluctuations | special composition with high thermal conductivity and special expansion coefficient |
| Single or double-pin high voltage output | single or double-pin high voltage output |
| Standards | EN 61558-1:1997 + A1:1998 +A11:2003, EN 61558-2-3:2000 |
| Thermal compound | special composition with high thermal conductivity and special expansion coefficient |
Choosing and fitting
Ignition transformers of this type are selected by matching the supply voltage, secondary voltage, and current ratings to the burner's requirements. The mounting system must align with the burner's design, often using M4x45 screws for direct controller attachment. The ignition cable length should not exceed the specified maximum, and the spark distance must be set within the recommended range. Compatibility with the burner's controller is essential, and various connection options (threaded or connector) are available to suit different installations.
Signs of failure
When ignition transformers fail, common symptoms include no spark or weak spark at the electrode, leading to ignition failure or intermittent burner operation. The transformer may overheat or produce a buzzing sound due to internal short circuits or component degradation. Check the secondary voltage output, spark gap, and cable integrity. Also inspect for signs of arcing or damage to the high-voltage output and ensure the supply voltage is within specifications.
All specifications
| Supply voltage | 220–240 V |
|---|---|
| Secondary voltage | 24 kV |
| Poles / outlets | 2 |
| Maximum length of ignition cable with integrated electronic ignition | 1.5 m |
| Standard power cable length | 560 mm |
| Recommended spark distance | 3–5 mm |
| Output voltage frequency | 6 kHz |
| Rated current (mA) | 27 mA |
| Ingress protection | IP00 |
| Output voltage max | 15 kV |
| Built-in filter | integrated EMC filter |
| Short-circuit protection | built-in |
| Varistor protection | built-in varistor |
| High-frequency generator | high-frequency electronic generator |
| Ferritic core | ferritic core |
| Mounting screw | M4x45 screws |
| Compatible controllers | Brahma controllers |
| Low voltage directive | 73/23/EEC |
| Electromagnetic interference protection | filter to reduce electromagnetic interference |
| External filter not required | no additional external filters required |
| Continuous operation | 100% duty cycle |
| Light weight | light weight |
| Compact size | compact size |
| High efficiency | high efficiency and ignition power |
| Mounting and connecting systems | various mounting and connecting systems |
| Installation ease | ease of installation |
| Maintenance requirement | ease of maintenance |
| Reliability | reliable operation |
| Certification | IMQ resolution |
| Safety standard | low voltage directive (LVD) 73/23/EEC |
| Secondary current | 55 mA |
| Duty cycle | 50 % |
| Net weight | 0.42 kg |
| Power consumption | low power consumption |
| Frequency | 50 Hz |
Part numbers
| SKU | 15910551 |
|---|---|
| Additional article | 246.820.009 |
| Model | TC2STCAF |